Section N- Main Control Box<br />

Power Panel 1/07 to present*<br />

Components<br />

Power Panel- MMP, Contactors, DS1 Disconnect Switches<br />

Sch. Part Part Voltage<br />

Sym. Description Number 208V 230V 460V 575V<br />

Manual Motor Protectors<br />

MMP10 MMP- Supply Fan Motor See 1 Page After Next<br />

MMP20 MMP- Return Fan Motor See 1 Page After Next<br />

Contactors<br />

M10 Contactor- Supply Fan Motor See 1 Page After Next<br />

M20 Contactor- Return Fan Motor See 1 Page After Next<br />

Disconnect Switch<br />

DS1 Disconnect Switch- Main Code 11= A2, B2, C2, D2<br />

Electric Heat (C04= E) units<br />

Switch- 100A 1 349935125 1 1 1 1<br />

Handle Kit 349935521 1 1 1 1<br />

Shaft 349962204 1 1 1 1<br />

Ground Lug 349938001 1 1 1 1<br />

Switch- 150A 1 349935126 1 1 1 1<br />

Handle Kit 349935532 1 1 1 1<br />

Shaft 349962205 1 1 1 1<br />

Ground Lug 349938001 1 1 1 1<br />

Switch- 250A 1 349935226 1 1 1 1<br />

Handle Kit 349935532 1 1 1 1<br />

Shaft 349962205 1 1 1 1<br />

Ground Lug 349938001 1 1 1 1<br />

Switch- 400A 1 349935325 1 1 1 1<br />

Handle Kit 349935621 1 1 1 1<br />

Shaft 349962206 1 1 1 1<br />

Ground Lug 349938002 1 1 1 1<br />

Switch- 600A 1, 2, 3, 4 193438205 1 1 1 1<br />

Handle 349961102 1 1 1 1<br />

Operating Mechanism 193455001 1 1 1 1<br />

Shaft 349961301 1 1 1 1<br />

Shaft- Mod 349962242 1 1 1 1<br />

Ground Lug 349938002 1 1 1 1<br />

Switch- 800A 1, 4 193438201 1 1 1 1<br />

Handle 349961102 1 1 1 1<br />

Operating Mechanism 193455001 1 1 1 1<br />

Shaft 349961301 1 1 1 1<br />

Shaft- Mod 349962242 1 1 1 1<br />

Ground Lug 349938003 1 1 1 1<br />

Switch- 1000A 1, 4 193438206 1 1 1 1<br />

Handle 349961102 1 1 1 1<br />

Operating Mechanism 193455001 1 1 1 1<br />

Shaft 349961301 1 1 1 1<br />

Shaft- Mod 349962242 1 1 1 1<br />

Ground Lug 349938003 1 1 1 1<br />

1 Any of the listed disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin McQuay Parts<br />

with unit serial and/or GO number to insure correct replacement is selected.<br />

2 The 600A switch listed is used on units with one disconnect or two disconnects EH/balance of unit (Code 11= A2 or B2).<br />

3 If unit has two disconnects where the second disconnect controls the fans (Code 11= C2) or 3 disconnects (Code 11= D2) then use<br />

switch p/n 193438002, handle kit p/n 193437901, shaft p/n 349962233, and ground lug p/n 349938002.<br />

4 Note that the original disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper<br />

installation.<br />

* Code 08= D. If unit was built between 10/06 and 12/06 contact Daikin McQuay Parts.<br />