Electrical Legend<br />
Schematic Sym. Description Location<br />
ACT1 Actuator Motor, Supply Fan Vanes Supply <strong>Air</strong> Section<br />
ACT2 Actuator Motor, Return Fan Vanes Return <strong>Air</strong> Section<br />
ACT4 Actuator Motor, Economizer Dampers Economizer Section<br />
ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section<br />
ACT6 Actuator Motor, Return <strong>Air</strong> Isolation Damper Return <strong>Air</strong> Section<br />
ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat<br />
ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool<br />
ACT 10, 11 Actuator Motors, Exhaust Dampers Return <strong>Air</strong> Section<br />
ACT12 Actuator Motor, Economizer Bypass Damper Heat Recovery Section<br />
ADI ADI Board Main Control Box<br />
AFD10 Adjustable Frequency Drive (Inverter), Supply Fan AFD or Supply Fan Sect.<br />
AFD20 Adjustable Frequency Drive (Inverter), Return Fan AFD or Supply Fan Sect.<br />
AS <strong>Blow</strong>er <strong>Air</strong> Switch Furnace Section<br />
BM Burner <strong>Blow</strong>er Motor Furnace Section<br />
C9, 10 Power Factor Capacitors, Supply Fan Supply <strong>Air</strong> Section<br />
CB10 Circuit Breaker, Supply Fan Main Control Box<br />
CB20 Circuit Breaker, Return Fan Main Control Box<br />
CPC Circuit Board, Main, MicroTech Controller Main Control Box<br />
CPR Circuit Board, Expansion, Main Controller Main Control Box<br />
DAT Discharge <strong>Air</strong> Temperature Sensor Discharge section<br />
DB1 Daughter Board Main Control Box<br />
DFLH Design Flow Sensor, Left Hand Return Section<br />
DFRH Design Flow Sensor, Right Hand Return Section<br />
DHL Duct High Limit Main Control Box<br />
DS1 Disconnect Main Control Box<br />
DS2 Disconnect, SAF/RAF/Controls Main Control Box<br />
DS3 Disconnect, Electric Heat Electric Heat Section<br />
DS6 Disconnect, Unit Supplied 120V Power Bulkhead<br />
EAT Exhaust <strong>Air</strong> Temperature Sensor Heat Recovery Section<br />
EFT Entering <strong>Air</strong> Temperature Sensor Supply Fan Section<br />
EXPA, B, D Expansion Board Main Control Box<br />
F1, 1A Fuse, Control Circuit, T1 Primary Main Control Box<br />
F1C Fuse, Control Circuit, T1 Secondary Main Control Box<br />
F2 Fuse, Control Circuit Condenser Control Box<br />
F3 Fuse, Burner Motor Main Control Box<br />
F4 Fuse, T4 Transformer Main Control Box<br />
FB8 Fuseblock, Main Transformer Main Control Box<br />
FB9, 10 Fuseblocks, Supply Fan Main Control Box<br />
FB19, 20 Fuseblocks, Return Fan Main Control Box<br />
FB31-40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Section<br />
FB41-50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Section<br />
FD Flame Detector Furnace Section<br />
FLC Fan Limit Control Furnace Section<br />
FS1 Freezestat Coil Section, Heat/Cool<br />
FSG Flame Safeguard Furnace Section<br />
GCB1 Generic Condenser Board Main Control Box<br />
GFS1/GFR1,2 Ground Fault Sensor/Relay Main Control Box<br />
GRD Ground All Control Boxes<br />
GV1 Gas Valve, Pilot Furnace Section<br />
GV2, 3 Gas Valves, Main Furnace Section<br />
GV4-8 Gas Valve, Hi-Turn Down Furnace Section<br />
HL 1-10 High Limits, Elec. Heaters, Power (Top Bank) Electric Heat Section<br />
HL 11-20 High Limits, Elec. Heaters, Power (Bottom Bank) Electric Heat Section<br />
<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 15