26.03.2013 Views

RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...

RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...

RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Section N- Main Control Box<br />

Power Panel— Until 3/05<br />

Fan Motor Contactors, Overloads and Fusing<br />

Components, Continued<br />

15 Horsepower Supply or Return Fan Motor- Code 22 or 32= M.<br />

Across- The- Line Start (C10= AL)<br />

Sch. Part Part Voltage<br />

Sym. Description<br />

Contactors<br />

Number 208V 230V 380V 460V 575V<br />

M10,20 Contactor- Supply (M10), Return (M20) Fan Motor 027514404 1 1<br />

Contactor- Supply (M10), Return (M20) Fan Motor<br />

Fuse Block and Fuses<br />

027514402 1 1 1<br />

FB10,20 Fuse Block- Supply (FB10), Return (FB20) Fan Motor 023780213 1<br />

Fuse Block- Supply (FB10), Return (FB20) Fan Motor 023780209 1<br />

Fuse Block- Supply (FB10), Return (FB20) Fan Motor 023780205 1 1 1<br />

Fuse- FB10 or FB20 025860515 3<br />

Fuse- FB10 or FB20 025860514 3<br />

Fuse- FB10 or FB20<br />

Overloads and Heaters<br />

OL10,20 Overload- Supply (OL10), Return (OL20) Fan Motor<br />

025860409 3 3 3<br />

Until 1/98 030189400 1<br />

Until 1/98 030189300 1<br />

Until 1/98 030189200 1 1 1<br />

1/98 and later<br />

Overload Heater- OL10,20<br />

059990101 1 1 1 1 1<br />

Standard Efficiency Motor (C22/32= _AY or _GY) 025861600 1 1<br />

Standard Efficiency Motor (C22/32= _AY or _GY) 026111700 1 1<br />

Standard Efficiency Motor (C22/32= _AY or _GY)<br />

High or Prem.Eff. Motor (C22/32= _EY,_FY,_JY,_KY)<br />

026114500 1<br />

1<br />

1/98 and later 059990616 1<br />

1/98 and later 059990615 1<br />

1/98 and later<br />

LR10,20 Line Reactors<br />

059990612 1 1 1<br />

2<br />

NOTE: Quantities Listed are PER motor.<br />

1 For High Efficiency motors used on units built prior to 1/98, see the Overload Heater Chart at the end of this section (located on the<br />

page following the 50HP motors).<br />

2 When the unit has an inverter with bypass (C14= 1, 2, 3, 4, 5, 8) the line reactors are located in the bypass box. When there is no inverter<br />

bypass box the Line Reactors are located in the Main Control Power Panel. The Line Reactor part numbers are listed in Section F.<br />

<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 179

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!