Section N- Main Control Box<br />
MicroTech II or No Controls Control Panel— 3/05 and later*<br />
Components<br />
* Code 08= D. Between 10/04 & 3/05 either this control panel or the original MicroTech II control panel (Code 08= P) could be installed.<br />
Check the GO or visually inspect the unit to verify which panel is installed. If built between 10/06 and 12/06 contact Daikin McQuay Parts.<br />
Sch. Part Part<br />
Sym. Description Number Qty.<br />
Main Controller<br />
MCB Main Controller- Must be programmed (unit GO# required) 060006101 1<br />
Com Card- Bacnet (C12= B*) 060006202 1<br />
Com Card- Bacnet with Ethernet (C12= E*) 060006201 1<br />
Com Card- LonMark Space Control (C12= LS) 060006203 1<br />
Com Card- LonMark Discharge Control (C12= LD) 060006204 1<br />
Standoff- Com Card 048166706 4<br />
Kit- Connector Repair 300036605 1<br />
Power Supply- 5 VDC 111049610<br />
Serial Port Ribbon Cable 111047201 1<br />
Battery 049754501 1<br />
Grounding Bar 349936901 1<br />
Keypad<br />
Keypad Keypad 060006301 1<br />
Remote Keypad Interface Board 112021601 1<br />
Cable- Interface 349938501 1<br />
Condenser Board<br />
GCB1 Expansion Board- Condenser 112026101 1<br />
Standoff- Expansion Board 048166705 7<br />
Com. Card- Bacnet 060006202 1<br />
Standoff- Com. Card 048166707 4<br />
RES Resistor- GCB1 060003901 1<br />
Electric Heat Board<br />
EHB1 Expansion Board- Electric Heat 112026101 1<br />
Standoff- Expansion Board 048166705 7<br />
Com. Card- Bacnet 060006202 1<br />
Standoff- Com. Card 048166707 4<br />
Switches- Control<br />
HS1 Switch- Electric Heat Shutdown (C04=E) 001355000 1<br />
S1 Switch- System On/Off<br />
Gas Heat Units C04= A 018446400 1<br />
Elec.,Steam,HW or No Heat C04=E,S,W,Y 001355000 1<br />
S4 Switch- Inverter Bypass On/Off 028798400 1<br />
S7 Switch- Local On/Auto/Off to Controller 349931201 1<br />
Serial Cables<br />
Serial Serial Cable 111047201 1<br />
Duct Hi Limit and Duct Static Pressure Sensors<br />
DHL Duct Hi Limit Switch 065493801 1<br />
SPS1 Pressure Transducer- Duct Sensor Code 13= 1, 2, 3 049545007 1<br />
SPS2 Pressure Transducer- Duct Sensor Code 13= 2 049545007 1<br />
Pressure Transducer- Space Sensor Code 13= 3, 4 049545006 1<br />
Time Delays<br />
TD9 Time Delay- SA Fan PW (Special) 1 Sec. 028210101 1<br />
TD19 Time Delay- RA Fan PW (Special) 1 Sec. 028210101 1<br />
<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 197