RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Section N- Main Control Box<br />
Control Panel- Units with MicroTech Controls<br />
(C12= 1M, 2M, 3M, 4M, 5M)— Until 1/01<br />
Components<br />
Sch. Part Part<br />
Sym. Description Number Qty.<br />
Relays, continued<br />
R24 Relay- Gas Heat Alarm 019643000 1<br />
R26 Relay- Powered Relief Dampers 019643000 1<br />
R27 Relay- Powered Relief Dampers 019643000 1<br />
R28 Relay- Isolation Damper 032508101 1<br />
R29 Relay- Final Filter 026213000 1<br />
R30 Relay- CW, Face & Bypass 019643000 1<br />
R65 Relay- PW Fan 073340001 1<br />
R66 Relay- PW Fan 073340001 1<br />
R67 Relay- Supply Fan with inverter 019643000 1<br />
R68 Relay- Return Fan with inverter 019643000 1<br />
R69 Relay- Inverter with Bypass 032508101 1<br />
Relay- Inverter without Bypass 019643000 1<br />
Transducer and Pressure Controls<br />
SPS1 Sensor- Duct Static Pressure (C13= 1, 2, 3) 049545005 1<br />
SPS2 Sensor- Duct Static Pressure (C13= 2) 049545005 1<br />
Sensor- Building Static Pressure (C13= 3, 4) 049545006 1<br />
DHL Switch- Duct Hi- Limit 065493801 1<br />
Fitting for DHL 049763002 1<br />
Main MicroTech Controller and Associated Boards<br />
MCB1 Microprocessor (must be programmed- requires unit GO or Serial No.) 065487306 1<br />
Fuse- MCB1 065822001 1<br />
Keypad Keypad/Display Assembly 065497201 1<br />
Ribbon Cable- MCB to Keypad 065499702 1<br />
ADI ADI Board 1 065816005 1<br />
OBA Output Board- 16 position 066542201 1<br />
Ribbon Cable- MCB to OBA 049265204 1<br />
OBB Output Board- 4 position- Cooling 066542203 1 3<br />
OBB Output Board- 8 position- Cooling 066542202 1 4<br />
OBC Output Board- 8 position- Heating 066542202 1 5<br />
OB_ _ Output Board Relay<br />
Positions OBA1-8, OBA13-16, OBB1-8, OBC1-8 049265601 2<br />
Positions OBA9- 12 no inverters (C14= Y) 049265601 2<br />
Positions OBA9- 12 units with inverters (C14= 1-9) 049265603 2<br />
SB1 Cooling Staging Board 065499001 1<br />
SB2 Heating Staging Board- 4 to 8 stages of Heat 065499001 1 5<br />
Room Sensors<br />
Sensor #1- Standard VAV 066540401 1 6<br />
Sensor #2- Enhanced VAV (includes tenant override) 066540402 1 6<br />
Sensor #9- Standard CAV 066540409 1 6<br />
1 Units built prior to 1995 used a Daughter Board (DB1) p/n 049545501 (the DB1 fuse is p/n 065829601 and the ribbon cable from MCB to<br />
DB1 is p/n 049265103).<br />
2 Quantity varies depending on options.<br />
3 Used on units with Evaporator Coils (C28 or C36= 5Z******) and 4 stages of cooling (C42= 4). Ribbon cable OBB to SB1 is p/n<br />
065499501.<br />
4 Used on units with Evaporator Coils (C28 or C36= 5Z******) and 6 or 8 stages of cooling (C42= 6 or 8). Ribbon cable OBB to SB1 is p/n<br />
065499501.<br />
5 Used on CAV units (C12= 1M or 5M) with more than 4 stages of electrical heat. Ribbon cable connecting OBC to SB2 is p/n 065499501.<br />
6 Prior to 1/92 use p/n 058899372 for VAV and p/n 065824701 for CAV.<br />
<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 167