<strong>NPort</strong> <strong>5110</strong> Series User’s <strong>Manual</strong> Web Console Configuration<br />

Operating Settings<br />

Real COM Mode<br />

Click on Operating Settings, located under Main Menu, to display the operating settings for both<br />

of <strong>NPort</strong> <strong>5110</strong>’s serial ports.<br />

TCP alive check time<br />

Setting Factory Default Necessity<br />

0 to 99 min 7 min Optional<br />

0 min: TCP connection is not closed due to an idle TCP connection.<br />

1 to 99 min: <strong>NPort</strong> <strong>5110</strong> automatically closes the TCP connection if there is no TCP activity for<br />

the given time. After the connection is closed, <strong>NPort</strong> <strong>5110</strong> starts listening for another Real COM<br />

driver connection from another host.<br />

Max connection<br />

Setting Factory Default Necessity<br />

1, 2, 3, 4 1 Required<br />

Max connection is usually used when the user needs to receive data from different hosts<br />

simultaneously. The factory default is 1. In this case, only one specific host can access this port of<br />

the <strong>NPort</strong> <strong>5110</strong>, and the Real COM driver on that host will have full control over the port.<br />

Max. connection 1:<br />

Allows only 1 host’s Real COM driver to open the specific <strong>NPort</strong> <strong>5110</strong> serial port.<br />

5-10