CALIFORNIA<br />

Clean Fuel Buses<br />

MY Diesel Path Alternative Fuel Path<br />

NOx+NMHC PM NOx+NMHC PM<br />

2007 0.2 0.01 0.2 0.01<br />

2008<br />

15% of new purchase ZEB’s<br />

for large fleet (> 200)<br />

2010<br />

15% of new purchase ZEB’s<br />

for large fleet (> 200)<br />

Additional In-Use Engine Retrofit Requirements:<br />

- Installation of certified (approved) NOx/PM reduction equipment<br />

- Places NO 2 requirement places constraints on devices in 2007<br />

Max NO 2 increase: 2007-2008: 30%; 2009+: 20%<br />

- Manufacturers may install uncertified equipment as certific. process progresses<br />

- Requires warranty coverage and in-use compliance testing<br />

Emission standards for Diesel or dual-fuel urban bus engine (g/bhp.h)<br />

MY NOx PM NMHC Formaldehyde CO<br />

2004-2006 0.5 0.01 0.05 0.01 5.0<br />

2007+ 0.2 0.01 0.05 0.01 5.0<br />

Heavy Duty<br />

HD Idling Emissions Reduction Program<br />

- 2008+ GVWR > 14 k lbs must have automatic engine shutoff if<br />

a) after 5 min if park. brake on; 15 min if park. brake off or b) cert. to 30 g/hr<br />

NOx over SET/FTR<br />

- Sleeper equipped trucks no longer exempted from idling reduction requirement<br />

- Delay of shutoff for < 30 min allowed for emission dev. performance (dash light requir.)<br />

- Override allowed by PTO operation<br />

As portion of idling reduction program, auxiliary power supplies are regulated<br />

- Primary engine certified 2007+: APU to be certified off-road (w/ Level 3 DPF) or<br />

routed ahead of primary engine DPF<br />

- Primary engine 2006 or earlier: APU engine needs to be off-road certified (no<br />

DPF required) 5 min still applies w/in 100 ft of restricted areas.<br />

- Scan tool allowed to extend idling to 60 min for service<br />

- Fuel fired heaters: must comply w/ LEV requirements for fuel fired heaters<br />

LEV requirement for shutoff above 40F does NOT apply<br />

Foreign Trucks required to meet emission limits when entering the State from<br />

outside the US<br />

Proposed Modification to Urban Bus Engines and Vehicles Rules<br />

NOx standard for Diesel Hybrid-Electric Buses: 1.8 g/bhp.h MY 2004-2005<br />

PM standard 0.01 g/bhp.h Test Procedure: SAE J2711<br />

ZEB regulation: Timelines for ZEB demonstration under review: postponement<br />

expected<br />