ON BOARD DIAGNOSTICS<br />
Requirements for Correct Operation of NOx Control Measures<br />
Application date: TA from 09 Nov 2006 FR from 01 Oct 2007<br />
1) In case of engine systems requiring a reagent, NH3 emissions over the<br />
applicable emissions test cycle, do not exceed 25ppm (mean value).<br />
2) Engine NOx control<br />
- Incorrect operation of the NOx control monitored => MI<br />
- NOx level >1,5 g/kWh above the applicable NOx limit (See p. 13) => MI<br />
- NOx level exceed OBD (7,0 g/kWh) => torque limiter activation<br />
- Record of the fault for at least 400 days or 9600 hours of engine operation<br />
- Alternative method possible if use of EGR only for NOx emission control<br />
3) Reagent control<br />
- Warning when level of reagent 50% => torque limiter activation<br />
- Reagent indicator on dashboard<br />
- Reagent tank empty => torque limiter activation<br />
- Wrong reagent quality/ concentration => torque limiter activation<br />
- Interruption in reagent dosing activity => torque limiter activation<br />
4) Torque limiter value of:<br />
- Max 60% of max torque for N3 > 16 tons, M1, M3/III and M3/B >7,5 tons<br />
- Max 75% of max torque for N1, N2, N3 ≤ 16 tons, 3.570°C<br />
6) Emission control monitoring system monitored for<br />
- electrical failures<br />
- removal or deactivation of any sensor<br />
- if failure not remedied within 50 hrs engine operation => torque limiter<br />