06.08.2013 Views

POSITIP 855 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH

POSITIP 855 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH

POSITIP 855 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

II - 3 Encoders and Measured Value Display<br />

Setting the display step with linear encoders<br />

With linear encoders, the display step depends on the<br />

• signal period of the encoder (P31.*) and the<br />

• linear subdivision (P32.*).<br />

Both parameters are entered separately for each axis. The linear<br />

subdivision can range from 0.1 to 128 depending on the signal<br />

period of your encoder.<br />

For linear measurement using nut/ballscrew arrangements and<br />

rotary encoders, calculate the signal period as follows:<br />

Signal period [µm] =<br />

Drivescrew pitch [mm] · 1000<br />

Line count<br />

Display step, signal period and linear subdivision for linear encoders<br />

Signal period [µm]<br />

Display step<br />

2 4 10 20 40 100 200 12 800<br />

[mm] [inch] Linear subdivision<br />

0.000 02 0.000 001 100 – – – – – – –<br />

0.000 05 0.000 002 40 80 – – – – – –<br />

0.000 1 0.000 005 20 40 100 – – – – –<br />

0.000 2 0.000 01 10 20 50 100 – – – –<br />

0.000 5 0.000 02 4 8 20 40 80 – – –<br />

0.001 0.000 05 2 4 10 20 40 100 – –<br />

0.002 0.000 1 1 2 5 10 20 50 100 –<br />

0.005 0.000 2 0.4 0.8 2 4 8 20 40 –<br />

0.01 0.000 5 0.2 0.4 1 2 4 10 20 –<br />

0.02 0.001 – – 0.5 1 2 5 10 –<br />

0.05 0.002 – – 0.2 0.4 0.8 2 4 –<br />

0.1 0.005 – – 0.1 0.2 0.4 1 2 128<br />

0.2 0.01 – – – – – – – 64<br />

94 Technical Information <strong>POSITIP</strong> <strong>855</strong>