SERVICE (cont.)<br />

BREW SELECTOR SWITCH (cont.)<br />

WHI/VIO to By-Pass Valve<br />

WHI/RED to Dispense Valve<br />

GRY to Interface Socket<br />

PNK to Interface Socket<br />

TAN to Interface Socket<br />

BLU to Timer<br />

ORN to Timer<br />

GRY to Grinder Interface<br />

TAN to Grinder Interface<br />

WHI/VIO to<br />

By-Pass Valve<br />

To Timer<br />

EARLY MODEL SELECTOR SWITCH<br />

4<br />

3<br />

2<br />

1<br />

5<br />

YEL to Timer<br />

WHI/RED to<br />

Dispense Valve<br />

LATE MODEL SELECTOR SWITCH<br />

P1388<br />

FIG. 4 BREW SELECTOR SWITCH TERMINALS<br />

Test Procedure (Late model Selector Switch):<br />

1. Disconnect the brewer from the power supply.<br />

2. Disconnect all wires from the brew selector<br />

switch.<br />

3. Check for continuity across terminals (b) and (1)<br />

when the switch is in the small batch position.<br />

Continuity must not be present in any other switch<br />

position.<br />

4. Check for continuity across terminals (b) and (2)<br />

when the switch is in the medium batch position.<br />

Continuity must not be present in any other position.<br />

d<br />

b<br />

e<br />

PNK<br />

PNK to Grinder Interface<br />

TAN<br />

GRY<br />

Page 13<br />

5. Check for continuity across terminals (e) and (5).<br />

When the selector switch is in the small batch<br />

position, continuity should not be present. When<br />

the selector switch is in the medium or large batch<br />

positions, continuity should be present.<br />

If continuity is present as described the switch is<br />

operating properly.<br />

If continuity is not present as described replace switch<br />

assembly.<br />

Removal and Replacement:<br />

1. Disconnect all wires from the brew selector<br />

switch.<br />

2. Loosen the set screw on the switch knob.<br />

3. Remove the 9/16" nut and washer holding the<br />

switch to the hood.<br />

4. Remove the switch.<br />

5. Install the new switch. The positioning tab must<br />

be in the hole in the hood for proper switch and<br />

knob alignment.<br />

6. Install the knob so that the arrow lines up in the<br />

large batch position when the switch is turned to<br />

the full right position.<br />

7. Refer to Fig. 4 when reconnecting the wires.<br />

41976 031709