TROUBLE<strong>SH</strong>OOTING (cont.)<br />

Problem<br />

Server will not heat<br />

Probable Cause<br />

1. Circuit breaker<br />

2. Receptacle Contacts<br />

3. Relay (Server Power) (Prior to<br />

S.N. <strong>DUAL</strong>026000)<br />

4. Transformer<br />

5. Rectifier<br />

Page 9<br />

Remedy<br />

A) Check and reset if necessary<br />

B) Refer to Service - Circuit breaker<br />

for test procedures.<br />

Clean or replace.<br />

Refer to Service - Relay (Soft Heat)<br />

for test procedures.<br />

Refer to Service - Transformer for<br />

test procedures.<br />

Refer to Service - Rectifier for test<br />

procedures.<br />

41976 031709