FROST BUILD UP - DISPENSER DOOR NOT CLOSING<br />

This unit was exchanged as being non repairable. If you are experiencing a “ice<br />

door not sealing condition, Examine this area to insure the dispenser wires are not in<br />

the way of the ice flapper door. A new part has been added at production to prevent<br />

this this issue from from occurring.<br />

PEX PEX Unit – Deemed Not repairable. repairable. The unit could have been easily easily repaired.<br />

No Seal<br />

Good Seal<br />

No Seal<br />

Good Seal<br />

To verify the ice door seal, press the ice flapper door against the ice chute to make an<br />

impression into the seal. Remove the flapper door. If you see an impression across<br />

all four sides of the ice chute, you have a good seal.<br />