18.08.2013 Views

UD-35 SERVICE UPDATE FIRST HALF—2009 - Whirlpool

UD-35 SERVICE UPDATE FIRST HALF—2009 - Whirlpool

UD-35 SERVICE UPDATE FIRST HALF—2009 - Whirlpool

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MAIN CONTROL<br />

The Gemini ES is the main control board and is mounted vertically with P1 in the topleft<br />

corner. Neither P1 nor P2 need shunting connectors. If the left two pins of P1<br />

are tied together on an M-line, the unit will go into manufacturing diagnostics mode<br />

each time it is powered up. The NTC (negative temperature coefficient) Thermistors<br />

are connected to connector P3. Line voltage AC inputs go into P4, and the switched<br />

neutral comes out of P4. P8 is in the bottom left corner and gets the AC power<br />

directly from the power switch. On the bottom right, AC outputs are driven out of<br />

P5. On the top right, DC outputs come out of P7. On the top left, the P6 connector<br />

provides 3-wire WISP communications with the user interface in the top of the refrigerator<br />

compartment (RC) from the top row of silo’s; the lower row of 3 silo’s are for<br />

older QUISP style communications.<br />

59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!