KABIR DIAGNOSTIC INVERTER<br />

This change will greatly improve the diagnosis of compressor, control and inverter<br />

failures.<br />

Note: Diagnostics aren’t foolproof. Since there is no communication between<br />

the inverter and the Gemini, the inverter displays the most likely failure. The<br />

intent is to point the Tech in the right direction.<br />

AIR DOOR<br />

•<br />

DIAGNOSTIC CODE<br />

• LED Off: No failure detected<br />

• 2 Flashes: No 3-6vdc signal from the<br />

control<br />

• 3 Flashes: Inverter failure<br />

• 4 Flashes: Compressor failure or full<br />

restriction<br />

Air door is driven by a stepper motor.<br />

- Each phase 370 Ω – 460 Ω<br />

- WH to BU and YL to RD should each be 370-460Ω<br />

- Operated by 12VDC pulses<br />

- 200 pulses/second<br />

- 1750 steps open to close<br />

78<br />

Note: Always check wires and connectors<br />

first<br />

During operation (diagnostic step 6), either AC or DC can be measured to ground (e.g. P6-6) VOM<br />

should show 6 to 8 V.<br />

Air Door<br />

VOM voltage readings will show “average” readings of 12V pulses. Diagnostic Step 6 will operate the<br />

door operate the door just once in each direction. On the French Door, diagnostic steps 11 and 14 operate<br />

the same way for the left & right bins, respectively.