PERFORMANCE <strong>UPDATE</strong><br />

(continued)<br />

•<br />

PERFORMANCE <strong>UPDATE</strong><br />

The ambient humidity effects the temperature values. These values are based<br />

on 70% humidity.<br />

Internal temperatures, 0º FC, 37º RC<br />

Crispers: Average, 2.5º-3.7º above RC temp.<br />

Temp. controlled pan:<br />

- At coldest setting, a window of approximately 4º below RC average temp.<br />

but greater then 26º.<br />

- Other than coldest setting: Temp setting of 32º or higher. The difference<br />

between the meat pan temp at coldest and warmest settings is<br />

designed to be be at least 4º.<br />

Ice mode: FC automatically goes to -5º F for auto max ice. This temp. may show<br />

on the display until the unit is out of auto max ice mode for a time.<br />

Warm Crisper Complaint SXS; Service<br />

kit being tested for models: M00,<br />

01, 02, 03, and T00.Only available<br />

through the Techline at this time.<br />

- Currently being trialed through<br />

engineering before<br />

the formal service kit is released.<br />

- Purpose of the kit is to improve<br />

the temperature performance in<br />

both the temp. controlled pan as<br />

well as the non-temp. controlled<br />

crisper pans.<br />

69<br />

Parts provided with pre-notched slots on<br />

air baffle assembly.<br />

Add new gasket on temp. control baffle.<br />

Verify the evaporator tube is installed and<br />

installed correctly.