SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

34 | section 5<br />

5. Align connectors JR2 and JR1 on the AES plug-in module with JP4 and JP3 on the<br />

motherboard. Likewise, align connector JP1 on the plug-in module with JP5 on the<br />

motherboard. (See figure below). Push firmly to seat the plug-in module onto the motherboard.<br />

Visually confirm that connector JR2 fits onto all four sets of pins on JP4, and<br />

JR1 connector fits onto all four sets of pins on JP3.<br />

6. Take the two mounting screws from the kit (1301-00077-100) and install them into the<br />

female side of the board standoffs in order to secure the AES I/O module to the hybrid<br />

motherboard.<br />

7. Reinstall the top cover using the 10 Phillips screws.<br />

8. Plug the AC power cord back into the socket and wait for the unit to power up. The hybrid<br />

unit will automatically detect the presence of the AES plug-in module, and directly transmit<br />

and receive digital data at the clock rate of the AES source plugged into the SEND IN<br />

XLR input connector.<br />

9. You can use the built-in diagnostic mode of the hybrid unit to confirm that the AES I/O<br />

module is working properly. Refer to Section 6 of the User’s <strong>Manual</strong> for instructions on<br />

how to enter this mode of operation. Test “T2” is a loopback test that takes audio present