3.01 Installation Requirements<br />

Electric Supply<br />

SECTION 3: INSTALLATION<br />

The electrical supply network, the gas and water supply system must meet local safety standards. This conformity<br />

shall be checked by qualified personnel.<br />

Input Power Input Current<br />

Voltage Freq. 3-Ph 3-Ph Fuse (Amps) Wire (AWG)<br />

(Volts) (Hz) (kVA) (Amps) 3-Ph 3-Ph<br />

208 50/60 74 206 260 #3/0 2<br />

Auto-Cut <strong>300</strong> Power Supply Input Power Specifications<br />

Suggested Sizes (See Note)<br />

230 50/60 72 181 230 #2 2<br />

400 50/60 75 109 135 #3 1<br />

400 (CE) 50/60 89 112 150 #2 1<br />

460 50/60 89 112 150 #2 1<br />

Line Voltages with Suggested Circuit Protection and Wire Sizes<br />

Based on National Electric Code and Canadian Electrical Code<br />

1<br />

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW<br />

2 Extra Hard Usage Type G, G-GC, W<br />

CAUTION<br />

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for<br />

the type and method of wire being used.<br />

Gas Supply<br />

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure regulators<br />

must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause one or<br />

more of the following problems:<br />

Reduced cutting speed<br />

Poor cut quality<br />

Poor cutting precision<br />

Reduced consumables life.<br />

Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.<br />

Cooling System Requirements<br />

Coolant must be added to the system on installation. The amount required varies with torch leads length.<br />

Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).<br />

Cat. Number and Mixture Mixture Protects To<br />

7-3580 'Extra-Cool TM ' 25 / 75 10° F / -12° C<br />

7-3581 'Ultra-Cool TM ' 50 / 50 27° F / -33° C<br />

7-3582 'Extreme CoolTM Coolant Capabilities<br />

' Concentrate* -65° F / -51° C<br />

* For mixing with D-I Cool TM 7-3583<br />

Manual No. 0-4817 Auto-Cut <strong>300</strong> 3-1 INSTALLATION