3.12 Height Control Connections<br />

The terminal strip has Arc Volts (-) connection to power supply negative output TORCH terminal, Arc Volts (+)<br />

connection to power supply positive output WORK terminal. These are for a height control that requires<br />

connection to the full non-divided arc voltage. Also available on the terminal strip are 120VAC (120,0) and 24<br />

VAC (24, 0). Note that the two 0’s are not common. The allowable current draw is 100ma @ 120VAC and 1Amp<br />

@ 24 VAC.<br />

Art # A-08404<br />

There is also a hole added in the rear panel above the J55-GCM receptacle for customer wiring. This, rather<br />

than the one in the CCM will be the preferred place for customer added wiring (and strain relief) for connections<br />

to height controls, etc..<br />

Manual No. 0-4817 Auto-Cut <strong>300</strong> 3-17 INSTALLATION<br />