Cutting Machine / Gantry<br />

Cutting Table<br />

1/0<br />

Ground Cable<br />

(F1)<br />

Earth Ground<br />

Rod<br />

Remote Arc<br />

Starter (RAS-1000)<br />

Cutting Machine / Gantry<br />

Cutting Table<br />

1/0<br />

Ground Cable<br />

(F1)<br />

Earth Ground<br />

Rod<br />

Torch<br />

1/0<br />

Ground Cable<br />

Customer supplied<br />

CNC<br />

Device<br />

0 - 10 ft (0 - 3 m) Ideal<br />

20 ft (6 m) Maximum<br />

Remote Arc<br />

Starter (RAS-1000)<br />

Star Ground on Cutting Table<br />

Torch<br />

CNC<br />

Device<br />

0 - 10 ft (0 - 3 m) Ideal<br />

20 ft (6 m) Maximum<br />

Power Supply<br />

Gas Control Module<br />

Primary location<br />

1/0 Work Cable<br />

1/0 Ground Cable<br />

‘Star’<br />

Ground<br />

Star Ground on Cutting Table<br />

1/0<br />

Ground Cable<br />

Customer supplied<br />

#4 AWG<br />

Ground<br />

(F)<br />

Gas Control Module<br />

Power Supply<br />

1/0 Work Cable<br />

‘Star’<br />

Ground<br />

Ultra-Cut<br />

or<br />

Auto-Cut O2<br />

Note: The gas control module can<br />

be mounted on top of the power<br />

supply.<br />

If it is, it should be grounded<br />

directly to the power supply with<br />

#4 AWG ground, (F).<br />

This alternate location requires<br />

grounding the power supply to the<br />

‘Star’ ground with the 1/0 Ground<br />

Cable (F1).<br />

Auto-Cut W/RAS<br />

#4 AWG Ground (F)<br />

(Factory Installed)<br />

Art # A-08253_AC<br />

Manual No. 0-4817 Auto-Cut <strong>300</strong> 3-8 INSTALLATION