NeuLAND - FAIR
NeuLAND - FAIR
NeuLAND - FAIR
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
clusters<br />
N<br />
clusters<br />
N<br />
clusters<br />
N<br />
100<br />
50<br />
100<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
50<br />
100<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
50<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
clusters<br />
N<br />
clusters<br />
N<br />
clusters<br />
N<br />
100<br />
50<br />
100<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
50<br />
100<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
50<br />
0<br />
0 500 1000 1500<br />
total light (a.u.)<br />
Figure 4.15.: Displayed is the number of clusters versus the total energy deposited for<br />
600 MeV neutrons. The upper left part shows the 1 neutron case, upper<br />
56<br />
right the 2 neutron case. In the middle left part multiplicity 3 events<br />
are plotted, and 4 neutron events in the middle right part of the figure.<br />
Accordingly the multiplicity 5 and 6 events are found in the lower left and<br />
right panels, respectively. For all neutron multiplicities the same number<br />
of events was calculated.