events<br />

300<br />

200<br />

100<br />

σ = 42 keV<br />

0<br />

0 0.5 1<br />

Erel<br />

(MeV)<br />

Figure 4.22.: Relative energy spectrum for four-neutron events at 600 MeV, simulated<br />

with a relative energy of 100 keV with respect to a projectile fragment and<br />

the <strong>NeuLAND</strong> detector in 35 m distance to the origin.<br />

this section). Again, from the further development of the neutron tracking algorithm,<br />

the 4-neutron-response is expected to improve.<br />

Quasi-Free Scattering<br />

<strong>NeuLAND</strong> in use for quasi-free scattering reactions will detect single neutrons, but a<br />

lower energies, see section 2.4. The detector will be located in close vicinity to the<br />

target, at an angle around 45 degree. The high efficiencies even for low energies are<br />

very important for this application. With a fully-active detector, we derive efficiencies<br />

of 79% for 50 MeV neutrons, 94% for 100 MeV, 95% for 150 MeV and 90 % for 200 MeV<br />

neutrons, respectively.<br />