35<br />
6. Construct the differentiator circuit. Apply a triangular wave <strong>of</strong> 1V <strong>and</strong> frequency <strong>of</strong><br />
1kHz. Monitor the input <strong>and</strong> output wave forms <strong>and</strong> sketch the output in Table I.<br />
7. Repeat step 3 for the difference amplifier.<br />
8. Test your design <strong>of</strong> the prelab <strong>and</strong> sketch the output in Table I.<br />
9. Construct the voltage to current converter circuit. Apply a sine wave <strong>of</strong> 1V <strong>and</strong><br />
frequency <strong>of</strong> 1kHz. Since the oscilloscope can not be use to measure current,<br />
measure the amplitude <strong>of</strong> the voltage V out for the two cases Z L =1kΩ <strong>and</strong> Z L =2kΩ.<br />
Then calculate I out in each case. Record your results in Table I.<br />