CV Designation Range Default Description<br />
#34 NMRA Function map F0 0 - 255 2 Function mapping for F0 reverse<br />
#35-46 Function mapp. F1 - F12 0 - 255 4,8,2,4,8,... Function mapping for F1 ... F12<br />
#47 ------<br />
#48 ------<br />
#49 HLU Acceleration 0 - 255 0 Multiplied by 0.4 = signal controlled acceleration<br />
#50 HLU Deceleration 0 - 255 0 Multiplied by 0.4 = signal controlled deceleration<br />
#51-55 HLU Limits 0 - 255 20,40,… Speed step for each of the 5 HLU speed limits<br />
#56 BEMF Parameter 1 - 255 55 PID regulation: P-Value (tens digit), I-Value (Ones digit)<br />
#57 Voltage reference 0 - 255 0 Value = 1/10 of fixed voltage. “0” = track voltage.<br />
#58 Back-EMF intensity 0 - 255 255 Load compensation at low speeds<br />
#59 HLU Reaction time 0 - 255 5 Delay for HLU changes, in tenth of a second<br />
#60 Dimming 0 - 255 0 Reduction of function output voltage through PWM.<br />
#61 ZIMO ext. mapping 1,2...97,98 0 Configurations not covered by NMRA mapping<br />
#62 Light effects mod. 0 - 9 0 Adjusts minimum dim value<br />
#63 Light effects mod. 0 - 99 51 Cycle time (tens digit), Off-time extension (ones digit)<br />
#64 Light effects mod. 0 - 9 5 Ditch light off-time modification<br />
#65 SW-Subversion # 0 - 255 - Completes the version number in CV #7.<br />
#66 Trim value forward 0 - 255 0 Multiplies speed step by trim value/128<br />
#67-94 Free speed table 0 - 255 0 Internal speed step for each of the 28 external steps<br />
#95 Trim value reverse 0 - 255 0 Multiplies speed step by trim value/128<br />
#96 ... ------<br />
105, 6 User data 0 - 255 0 Free memory space for user data<br />
#107 Light suppression 0 - 255 0 Light suppression for cab 1 (forward)<br />
#108 Light suppression 0 - 255 0 Light suppression for cab 2 (rear)<br />
109 … ------<br />
#112<br />
Special ZIMO<br />
configuration bits<br />
0 - 255<br />
4 =<br />
00000100<br />
also Bit 2 = 1<br />
(Loco ID pulses<br />
ON,<br />
20 kHz)<br />
Bit 1 = 1: High frequency acknowledgements<br />
Bit 2 = 0 / 1: ZIMO loco ID ON/OFF<br />
Bit 3 = 1: 8 Functions-Mode (for old ZIMO systems)<br />
Bit 4 = 1: Pulse chain recognition (for old LGB-System)<br />
Bit 5 = 0 / 1: Motor control at 20 kHz or 40 kHz<br />
Bit 6 = 1: „Märklin“-Braking (+ CV # 29, Bit 2, # 124, 5)<br />
#113 BEMF reduction 0 - 255 0 Intensity reduced at speed step defined in CV #10.<br />
#114 Dim Mask 1 Bits 0 - 7 0 Individual outputs exempted from dimming per CV #60<br />
#115 Coupler control 0 - 99 0 Eff 48: Pull-in V. (tens digit), Hold voltage (ones digit)<br />
#116 Autom. uncoupling 0 - 199 0 Unload (Hundredth) Separat.(Tens), speed (Ones digit)<br />
#117 Flasher 0 - 99 0 ON time (Tens digit), OFF time (Ones digit)<br />
#118 Flasher mask Bits 0 - 7 0 Function outputs included for flashing as per CV #117.<br />
#119 F6 low beam mask Bits 0 - 7 0 Enter FO for low-beam switching with F6 as per CV #60<br />
#120 F7 low beam mask Bits 0 - 7 0 Enter FO for low-beam switching with F7 as per CV #60<br />
#121 Expon. acceleration 0 - 99 0 Speed range included (Tens digit), curve (Ones digit)<br />
#122 Expon. deceleration 0 - 99 0 Speed range included (Tens digit), curve (Ones digit)<br />
#123 Adapt. accel./decel. 0 - 99 0 Accel. Convergence (Tens dig.), Decel. Conv. (Ones…)<br />
#124 Shunting key 1 Bits 0-4, 6 0<br />
#125<br />
#126<br />
#127<br />
#128<br />
#129<br />
#130<br />
#131<br />
#132<br />
Effects F0 front<br />
F0 rear<br />
F1<br />
F2<br />
F3<br />
F4<br />
F5<br />
F6<br />
#133 ------<br />
0 - 255 0<br />
Shunting key (for half speed, accel. deactivation),<br />
Switch between SUSI – Logic level outputs<br />
Bits 1, 0 = 00: directional (active in both directions)<br />
= 01: only forward<br />
= 10: only reverse<br />
Bits 7, 6, 5, 4, 3, 2 = Effect-Code, i.e.:<br />
Uncoupler - 00110000 = “48”<br />
Soft-Start for function output - 00110100 = “52”<br />
Autom. Brake light - 00111000 = „56“<br />
and so on.<br />
#134 Asymm. stops (ABC) 1-14,101,, 106 Sensitivity (Hundredth), Threshold (Tens, ones digit).<br />
#135 km/h - Control 2 - 20 0 = 1 Calibration run; 5, 10, 20: Relation km/ spd. step<br />
#136 km/h - Control or: RailCom Contr. value after cal-run; or correct. value for RailCom<br />
#137<br />
#138<br />
#139<br />
Smoke generator<br />
characteristics<br />
0 - 255<br />
0 - 255<br />
0 - 255<br />
0<br />
0<br />
0<br />
Eff 72,80: CV #137: PWM of FOx at stand still<br />
CV #138: PWM of FOx at cruising speed<br />
CV #139: PWM of FOx during acceleration<br />
#140 Distance controlled stop 0-3,11-13 0 = 1: HLU or ABC = 2: manual = 3: both<br />
#141 Distance controlled stop 0 - 255 0 “Constant distance”: Stop point = 155: 500 m<br />
#142 Distance controlled stop 0 - 255 12 High speed correction for ABC<br />
#143 Distance controlled stop 0 - 255 0 High speed correction for HLU<br />
#144 Prog,/ Update Lock Bits 6, 7 0 Bit 6 = 1: „Service mode“-Lock, Bit 7 = 1: Update-Lock<br />
#145 ------<br />
#146 Gear backlash compen. 0 - 255 0 Hundredth’ of a second at min. speed after dir.-change<br />
147,… Experimental-CV‘s 0 - 255 0 Special motor regulation settings<br />
#151 Motor brake 0 - 9 0 = 1 … 9: Force and speed of application<br />
#152 Dim Mask 2 Bits 0 - 7 0 Individual outputs exempted from dimming per CV #60<br />
#153 Continue w/o signal 0 - 255 0 Tenth of seconds: stop after losing DCC signal<br />
#154 Special OEM-Bits<br />
#155 Half speed 0 - 19 0 Function key selection (instead of CV #124)<br />
#156 Momentum deactivation 0 - 19 0 Function key selection (instead of CV #124)<br />
#157 MAN-Function 0 - 19 0 Function key selection<br />
158, ... ------<br />
#159 Effects on F7 0 - 255 0 Same as CV“s #125 – 132 but for F7