Decoder MX620 - MX622, MX630 - MX632 Sound Decoder MX640 - MX648<br />

CV Designation Range Default Description<br />

#34 NMRA Function map F0 0 - 255 2 Function mapping for F0 reverse<br />

#35-46 Function mapp. F1 - F12 0 - 255 4,8,2,4,8,... Function mapping for F1 ... F12<br />

#47 ------<br />

#48 ------<br />

#49 HLU Acceleration 0 - 255 0 Multiplied by 0.4 = signal controlled acceleration<br />

#50 HLU Deceleration 0 - 255 0 Multiplied by 0.4 = signal controlled deceleration<br />

#51-55 HLU Limits 0 - 255 20,40,… Speed step for each of the 5 HLU speed limits<br />

#56 BEMF Parameter 1 - 255 55 PID regulation: P-Value (tens digit), I-Value (Ones digit)<br />

#57 Voltage reference 0 - 255 0 Value = 1/10 of fixed voltage. “0” = track voltage.<br />

#58 Back-EMF intensity 0 - 255 255 Load compensation at low speeds<br />

#59 HLU Reaction time 0 - 255 5 Delay for HLU changes, in tenth of a second<br />

#60 Dimming 0 - 255 0 Reduction of function output voltage through PWM.<br />

#61 ZIMO ext. mapping 1,2...97,98 0 Configurations not covered by NMRA mapping<br />

#62 Light effects mod. 0 - 9 0 Adjusts minimum dim value<br />

#63 Light effects mod. 0 - 99 51 Cycle time (tens digit), Off-time extension (ones digit)<br />

#64 Light effects mod. 0 - 9 5 Ditch light off-time modification<br />

#65 SW-Subversion # 0 - 255 - Completes the version number in CV #7.<br />

#66 Trim value forward 0 - 255 0 Multiplies speed step by trim value/128<br />

#67-94 Free speed table 0 - 255 0 Internal speed step for each of the 28 external steps<br />

#95 Trim value reverse 0 - 255 0 Multiplies speed step by trim value/128<br />

#96 ... ------<br />

105, 6 User data 0 - 255 0 Free memory space for user data<br />

#107 Light suppression 0 - 255 0 Light suppression for cab 1 (forward)<br />

#108 Light suppression 0 - 255 0 Light suppression for cab 2 (rear)<br />

109 … ------<br />

#112<br />

Special ZIMO<br />

configuration bits<br />

0 - 255<br />

4 =<br />

00000100<br />

also Bit 2 = 1<br />

(Loco ID pulses<br />

ON,<br />

20 kHz)<br />

Bit 1 = 1: High frequency acknowledgements<br />

Bit 2 = 0 / 1: ZIMO loco ID ON/OFF<br />

Bit 3 = 1: 8 Functions-Mode (for old ZIMO systems)<br />

Bit 4 = 1: Pulse chain recognition (for old LGB-System)<br />

Bit 5 = 0 / 1: Motor control at 20 kHz or 40 kHz<br />

Bit 6 = 1: „Märklin“-Braking (+ CV # 29, Bit 2, # 124, 5)<br />

#113 BEMF reduction 0 - 255 0 Intensity reduced at speed step defined in CV #10.<br />

#114 Dim Mask 1 Bits 0 - 7 0 Individual outputs exempted from dimming per CV #60<br />

#115 Coupler control 0 - 99 0 Eff 48: Pull-in V. (tens digit), Hold voltage (ones digit)<br />

#116 Autom. uncoupling 0 - 199 0 Unload (Hundredth) Separat.(Tens), speed (Ones digit)<br />

#117 Flasher 0 - 99 0 ON time (Tens digit), OFF time (Ones digit)<br />

#118 Flasher mask Bits 0 - 7 0 Function outputs included for flashing as per CV #117.<br />

#119 F6 low beam mask Bits 0 - 7 0 Enter FO for low-beam switching with F6 as per CV #60<br />

#120 F7 low beam mask Bits 0 - 7 0 Enter FO for low-beam switching with F7 as per CV #60<br />

#121 Expon. acceleration 0 - 99 0 Speed range included (Tens digit), curve (Ones digit)<br />

#122 Expon. deceleration 0 - 99 0 Speed range included (Tens digit), curve (Ones digit)<br />

#123 Adapt. accel./decel. 0 - 99 0 Accel. Convergence (Tens dig.), Decel. Conv. (Ones…)<br />

#124 Shunting key 1 Bits 0-4, 6 0<br />

#125<br />

#126<br />

#127<br />

#128<br />

#129<br />

#130<br />

#131<br />

#132<br />

Effects F0 front<br />

F0 rear<br />

F1<br />

F2<br />

F3<br />

F4<br />

F5<br />

F6<br />

#133 ------<br />

0 - 255 0<br />

Shunting key (for half speed, accel. deactivation),<br />

Switch between SUSI – Logic level outputs<br />

Bits 1, 0 = 00: directional (active in both directions)<br />

= 01: only forward<br />

= 10: only reverse<br />

Bits 7, 6, 5, 4, 3, 2 = Effect-Code, i.e.:<br />

Uncoupler - 00110000 = “48”<br />

Soft-Start for function output - 00110100 = “52”<br />

Autom. Brake light - 00111000 = „56“<br />

and so on.<br />

#134 Asymm. stops (ABC) 1-14,101,, 106 Sensitivity (Hundredth), Threshold (Tens, ones digit).<br />

#135 km/h - Control 2 - 20 0 = 1 Calibration run; 5, 10, 20: Relation km/ spd. step<br />

#136 km/h - Control or: RailCom Contr. value after cal-run; or correct. value for RailCom<br />

#137<br />

#138<br />

#139<br />

Smoke generator<br />

characteristics<br />

0 - 255<br />

0 - 255<br />

0 - 255<br />

0<br />

0<br />

0<br />

Eff 72,80: CV #137: PWM of FOx at stand still<br />

CV #138: PWM of FOx at cruising speed<br />

CV #139: PWM of FOx during acceleration<br />

#140 Distance controlled stop 0-3,11-13 0 = 1: HLU or ABC = 2: manual = 3: both<br />

#141 Distance controlled stop 0 - 255 0 “Constant distance”: Stop point = 155: 500 m<br />

#142 Distance controlled stop 0 - 255 12 High speed correction for ABC<br />

#143 Distance controlled stop 0 - 255 0 High speed correction for HLU<br />

#144 Prog,/ Update Lock Bits 6, 7 0 Bit 6 = 1: „Service mode“-Lock, Bit 7 = 1: Update-Lock<br />

#145 ------<br />

#146 Gear backlash compen. 0 - 255 0 Hundredth’ of a second at min. speed after dir.-change<br />

147,… Experimental-CV‘s 0 - 255 0 Special motor regulation settings<br />

#151 Motor brake 0 - 9 0 = 1 … 9: Force and speed of application<br />

#152 Dim Mask 2 Bits 0 - 7 0 Individual outputs exempted from dimming per CV #60<br />

#153 Continue w/o signal 0 - 255 0 Tenth of seconds: stop after losing DCC signal<br />

#154 Special OEM-Bits<br />

#155 Half speed 0 - 19 0 Function key selection (instead of CV #124)<br />

#156 Momentum deactivation 0 - 19 0 Function key selection (instead of CV #124)<br />

#157 MAN-Function 0 - 19 0 Function key selection<br />

158, ... ------<br />

#159 Effects on F7 0 - 255 0 Same as CV“s #125 – 132 but for F7