<strong>REVISTA</strong> ROMÂNĂ <strong>DE</strong> AUTOMATICĂ<br />

31<br />

cooling are more economical (the electric<br />

consumption is reduces with 18%).<br />

Nevertheless, the systems with indirect<br />

cooling are being used due to the advantages<br />

given by: the possibility of using ammonia,<br />

the most advanced, the cheapest and most<br />

ecological refrigerant; it uses a low quantity<br />

of refrigerant with a favorable influence over<br />

the ambient; the possibility of being used in<br />

district cooling systems.<br />

Both systems have evolved towards variants<br />

with reversible functioning (insuring both the<br />

air conditioning and the building heating) or<br />

with heat recovery, which improve more and<br />

more their performances.<br />

Further, we present the experimental data for<br />

the specific indicators, for the production of<br />

menial refrigeration and air conditioning,<br />

using the most customary refrigerant<br />

(R134a).<br />

3.1. MENIAL REFRIGERATION<br />

The average energy consumption was<br />

calculated for certain equipments in<br />

accordance with the size of the menial<br />

consumer.One observes a continuous drop of<br />

the specific consumption caused by the<br />

equipment’s performance improvement.<br />

Table 4. Energy consumption for the production of menial refrigeration<br />

No. Living space Cooling volume of<br />

refrigerator, [l]<br />

Average<br />

consumption of<br />

Specific<br />

consumption<br />

Refrigeration Freezing electrical power, [10 -3 kW/(day,l)]<br />

[kWh/24h]<br />

1. Studio flat 228 20 0,71 2,87<br />

2. Ap. 2 rooms 322 70 0,89 2,37<br />

3. Ap. 3 rooms 425 99 1,17 2,22<br />

4. Ap.4-5 rooms 522 165 1,43 2,08<br />

3.2. AIR CONDITIONING ENERGY CONSUMPTION (working time 10 hours/day)<br />

3.2.1. Direct evaporation systems<br />

Tabel 5. Specific air conditioning indicators with direct evaporation systems<br />

No. Living space Type of air<br />

conditioning<br />

unit<br />

Cooling<br />

capacity,<br />

[kW]<br />

Electrical<br />

power,<br />

[kW]<br />

Average<br />

consumption<br />

of electrical<br />

power<br />

[kWh/24h]<br />

Specific<br />

consumption<br />

[kW/(m 2 ,zi)]<br />

1. Studio flat Monosplit 1,5 0,325 3,25 0,13<br />

2. Ap.2 rooms (2 UI) 2,4 0,47 4,7 0,1175<br />

3. Ap.3 rooms (3 UI) 3,6 0,72 7,2 0,12<br />

4. Ap.4-5 rooms (4-5 UI) 4,8 – 7,2 0,94….1,37 9,4…13,7 0,1175 ..0,114<br />

3.2.2. Indirect cooling systems with secondary refrigerant.<br />

Tabel 6. Specific air conditioning indicators with indirect cooling systems<br />

No. Living space Cooling<br />

capacity,<br />

[kW]<br />

Electrical<br />

power,<br />

[kWh/24h]<br />

Average<br />

consumption of<br />

electrical power<br />

[kWh/24h<br />

Specific<br />

consumption<br />

kW/(m 2 ,zi)]<br />

1. Studio flat 1,5 0,398 3,98 0,159<br />

2. Ap. 2 rooms 2,4 0,572 5,72 0,143<br />

3. Ap.3 rooms 3,6 0,855 8,55 0,1425<br />

4. Ap. 4 -5 rooms 4,8 – 7,2 1,12….1,68 11,2…16,8 0,14