cooling are more economical (the electric<br />
consumption is reduces with 18%).<br />
Nevertheless, the systems with indirect<br />
cooling are being used due to the advantages<br />
given by: the possibility of using ammonia,<br />
the most advanced, the cheapest and most<br />
ecological refrigerant; it uses a low quantity<br />
of refrigerant with a favorable influence over<br />
the ambient; the possibility of being used in<br />
district cooling systems.<br />
Both systems have evolved towards variants<br />
with reversible functioning (insuring both the<br />
air conditioning and the building heating) or<br />
with heat recovery, which improve more and<br />
more their performances.<br />
Further, we present the experimental data for<br />
the specific indicators, for the production of<br />
menial refrigeration and air conditioning,<br />
using the most customary refrigerant<br />
(R134a).<br />
3.1. MENIAL REFRIGERATION<br />
The average energy consumption was<br />
calculated for certain equipments in<br />
accordance with the size of the menial<br />
consumer.One observes a continuous drop of<br />
the specific consumption caused by the<br />
equipment’s performance improvement.<br />
Table 4. Energy consumption for the production of menial refrigeration<br />
No. Living space Cooling volume of<br />
refrigerator, [l]<br />
Average<br />
consumption of<br />
Specific<br />
consumption<br />
Refrigeration Freezing electrical power, [10 -3 kW/(day,l)]<br />
[kWh/24h]<br />
1. Studio flat 228 20 0,71 2,87<br />
2. Ap. 2 rooms 322 70 0,89 2,37<br />
3. Ap. 3 rooms 425 99 1,17 2,22<br />
4. Ap.4-5 rooms 522 165 1,43 2,08<br />
3.2. AIR CONDITIONING ENERGY CONSUMPTION (working time 10 hours/day)<br />
3.2.1. Direct evaporation systems<br />
Tabel 5. Specific air conditioning indicators with direct evaporation systems<br />
No. Living space Type of air<br />
conditioning<br />
unit<br />
Cooling<br />
capacity,<br />
[kW]<br />
Electrical<br />
power,<br />
[kW]<br />
Average<br />
consumption<br />
of electrical<br />
power<br />
[kWh/24h]<br />
Specific<br />
consumption<br />
[kW/(m 2 ,zi)]<br />
1. Studio flat Monosplit 1,5 0,325 3,25 0,13<br />
2. Ap.2 rooms (2 UI) 2,4 0,47 4,7 0,1175<br />
3. Ap.3 rooms (3 UI) 3,6 0,72 7,2 0,12<br />
4. Ap.4-5 rooms (4-5 UI) 4,8 – 7,2 0,94….1,37 9,4…13,7 0,1175 ..0,114<br />
3.2.2. Indirect cooling systems with secondary refrigerant.<br />
Tabel 6. Specific air conditioning indicators with indirect cooling systems<br />
No. Living space Cooling<br />
capacity,<br />
[kW]<br />
Electrical<br />
power,<br />
[kWh/24h]<br />
Average<br />
consumption of<br />
electrical power<br />
[kWh/24h<br />
Specific<br />
consumption<br />
kW/(m 2 ,zi)]<br />
1. Studio flat 1,5 0,398 3,98 0,159<br />
2. Ap. 2 rooms 2,4 0,572 5,72 0,143<br />
3. Ap.3 rooms 3,6 0,855 8,55 0,1425<br />
4. Ap. 4 -5 rooms 4,8 – 7,2 1,12….1,68 11,2…16,8 0,14