1.6 Getting Started — Register Mode (Mode 3)<br />

+24VDC Out<br />

PLC or<br />

similar<br />

Position reached<br />

Start<br />

Pause<br />

D5<br />

D4<br />

D3<br />

D2<br />

D1<br />

D0<br />

Ground<br />

AMC11B/12B does not use<br />

terminals P- and P+ since it<br />

includes a mains supply.<br />

See Power Supply section!<br />

Industrybus in<br />

<strong>User</strong>Outputs<br />

<strong>User</strong>Inputs<br />

IA1<br />

IA2<br />

IA3<br />

IA4<br />

O+<br />

O8<br />

O7<br />

O6<br />

O5<br />

O4<br />

O3<br />

O2<br />

O1<br />

O-<br />

IN8<br />

IN7<br />

IN6<br />

IN5<br />

IN4<br />

IN3<br />

IN2<br />

IN1<br />

IN-<br />

1C<br />

2C<br />

3C<br />

4C<br />

5C<br />

6C<br />

7C<br />

8C<br />

9C<br />

10C<br />

11C<br />

12C<br />

13C<br />

14C<br />

15C<br />

16C<br />

17C<br />

18C<br />

19C<br />

20C<br />

21C<br />

22C<br />

23C<br />

24C<br />

25C<br />

26C<br />

27C<br />

28C<br />

29C<br />

30C<br />

31C<br />

32C<br />

1A<br />

2A<br />

3A<br />

4A<br />

5A<br />

6A<br />

7A<br />

8A<br />

9A<br />

10A<br />

11A<br />

12A<br />

13A<br />

14A<br />

15A<br />

16A<br />

17A<br />

18A<br />

19A<br />

20A<br />

21A<br />

22A<br />

23A<br />

24A<br />

25A<br />

26A<br />

27A<br />

28A<br />

29A<br />

30A<br />

31A<br />

32A<br />

P-<br />

P+<br />

FA<br />

FB<br />

FC<br />

FD<br />

PDO<br />

IB1<br />

IB2<br />

IB3<br />

IB4<br />

HLA<br />

HLB<br />

HLC<br />

5VO<br />

EZ1<br />

EZ2<br />

EA1<br />

EA2<br />

EB1<br />

EB2<br />

ECM<br />

XCM<br />

XI<br />

YCM<br />

YI<br />

O5V<br />

AO<br />

BO<br />

OCM<br />

AIN<br />

ACM<br />

26B NL<br />

27B PL<br />

28B HM<br />

30B AX2<br />

31B TCM<br />

32B TAC<br />

PowerSupply in<br />

15-80V DC<br />

PowerDump output<br />

Industrybus out<br />

HallInput<br />

Screen<br />

PulseInputs<br />

Pulse Outputs<br />

+/-10VInput<br />

Screen<br />

End-of-travelinputs<br />

Secondary axis<br />

Analogue output<br />

(torque monitor)<br />

+<br />

From zero-point<br />

sensor<br />

Home (Reset) input<br />

TT0019GB<br />

Follow the procedure below for operation of the Controller in Mode 3 (Register Mode)<br />

1. Connect the Controller as shown above. For further details, see: Motor Connection, page 21 / <strong>User</strong><br />

Inputs, page 24 / <strong>User</strong> Outputs, page 27 / Encoder Input, page 28 / Power Supply, page 31.<br />

2. Connect the PC via a terminal program (e.g. <strong>JVL</strong>’s MotoWare or Windows Terminal), if necessary<br />

following the description of the RS232 interface in RS232 Interface, page 38.<br />

3. Switch on the Controller, but ensure that all inputs are inactive. Only the Power LED and possibly<br />

Out 1 may be active. If one or more of the red LEDs is active or blinks, the Controller is most likely<br />

set up for the wrong motor type. Follow the instructions in General Aspects of Installation, page 12<br />

4. Send the command ? (enter) to the Controller and wait until the Controller responds with a status<br />

overview.<br />

If the status overview is displayed, the RS232 interface and power supply are connected correctly.<br />

5. Set the Controller to Register Mode by sending the command MO=3 (enter).<br />

The Controller should respond Y, indicating that Register Mode has been selected.<br />

6. By default, the servo parameters KD, KP, and KI are set to typical, moderate values. This means<br />

that the motor can be operated without further adjustment. For optimum system operation however,<br />

the parameters must be adjusted. See Adjustment of Servo Regulation, page 16.<br />

7. The Controller is now set to Register Mode. As a test, connect a voltage to input 1 and 8 (start input).<br />

The motor should move to position 1000. This value is stored by default in register XP1 on delivery.<br />

For further information on operation in Mode 3, see Register Mode (MO=3), page 49<br />