3.15 RS485 Interface<br />

The controller include RS485 beside the normal RS232 interface. The RS485 interface is intended for<br />

purposes where 1 to 32 controllers are connected at the same line in a noisy environment.<br />

B / -<br />

Terminator<br />

Connect to A if<br />

Controller is the last<br />

Unit on the line<br />

9<br />

8<br />

5<br />

4<br />

Signal ground<br />

A / +<br />

TT0059GB<br />

The communication protocol is exatly the same as RS232. The only difference is the balanced signallines,<br />

end the fact that all communication is half duplex wich means that the controller can not send and<br />

receive at the same time as by use of RS232.<br />

The RS485 interface makes it possible to connect up to 32 units at the same lines.<br />

At the last controller the terminal called Terminator (pin 8) must be shorted to the A terminal (pin 4).<br />

Following illustration shows a typical system with 2 or more units connected to a computer or similar.<br />

Controller<br />

Address 1<br />

Controller<br />

Address 2<br />

Master<br />

Computer, PLC<br />

or similar<br />

GND<br />

B / -<br />

A / +<br />

5 5<br />

9 9<br />

4<br />

8 4<br />

Terminator<br />

To controller 3....32<br />

Connect to A if<br />

Controller is the last<br />

Unit on the line<br />

TT0060GB<br />

The RS485 feature is available at controllers with serial numbers higher than 5500.<br />