Note: Wrong setting will cause error alarm triggered. It is suggest using the device<br />
sing NC. This means that when it is triggered, or connection cut off, it will trigger<br />
alarm.<br />
Output Control Setup<br />
Output control is mainly controlling the relay output. Relay output itself is only the on/off<br />
device. It is not with any power signal output. So other than connect it to the needed<br />
devices, necessary power will need to connect as well.<br />
If output setting is “ON”, this means under normal condition, relay output is open loop<br />
circuit, after activated; relay output will become close loop circuit.<br />
If output setting is “OFF”, this means under normal condition, relay output is close loop<br />
circuit, after activated; relay output will become open loop circuit.<br />
Output not controllable when output setup is “---“<br />
Output Control<br />
When<br />
output control button is pressed, the following picture will be shown:<br />
MUTE/OUTPUT CONTROL<br />
1.MUTE<br />
2.OUTPUT1 OFF<br />
3.OUTPUT2 OFF<br />
4.OUTPUT3 OFF<br />
5.OUTPUT4 OFF<br />
1.Use this output control to shut off the alarm sound when alarm triggered.<br />
2.Use up, down buttons to select the outputs and press select button to adjust output<br />