Note: Wrong setting will cause error alarm triggered. It is suggest using the device<br />

sing NC. This means that when it is triggered, or connection cut off, it will trigger<br />

alarm.<br />

Output Control Setup<br />

Output control is mainly controlling the relay output. Relay output itself is only the on/off<br />

device. It is not with any power signal output. So other than connect it to the needed<br />

devices, necessary power will need to connect as well.<br />

If output setting is “ON”, this means under normal condition, relay output is open loop<br />

circuit, after activated; relay output will become close loop circuit.<br />

If output setting is “OFF”, this means under normal condition, relay output is close loop<br />

circuit, after activated; relay output will become open loop circuit.<br />

Output not controllable when output setup is “---“<br />

Output Control<br />

When<br />

output control button is pressed, the following picture will be shown:<br />

MUTE/OUTPUT CONTROL<br />

1.MUTE<br />

2.OUTPUT1 OFF<br />

3.OUTPUT2 OFF<br />

4.OUTPUT3 OFF<br />

5.OUTPUT4 OFF<br />

1.Use this output control to shut off the alarm sound when alarm triggered.<br />

2.Use up, down buttons to select the outputs and press select button to adjust output<br />

from OFF→ON or ON→OFF.<br />