For Technical Support Call 1-800-247-6557<br />
...Setup Menu Functions - Advanced...<br />
...Sets Minimum Key Force / Alignment Test 11 [PM_TAB11]<br />
Continued from the previous page.<br />
<strong>Ancho</strong> <strong>V69</strong>_1<br />
P M _ T A B 1 1 : K E Y 0 5 2 0 . 0 %<br />
P M _ T A B 1 1 : K E Y 0 6 2 5 . 5 %<br />
P M _ T A B 1 1 : K E Y 0 6 / 2 5 . 5<br />
1<br />
Press the “PREVIOUS” button to point the arrow<br />
toward the key number.<br />
2 Rotate the ADJust dial to play the next key.<br />
3<br />
Press the “NEXT” button so that the arrow points<br />
toward the percentage value.<br />
Rotate the ADJust dial so that the key plays as<br />
P M _ T A B 1 1 : K E Y 0 6 / 2 2 . 0 4<br />
softly as possible.<br />
Repeat the four steps above until all playable keys have been calibrated.<br />
P M _ T A B 1 1 : K E Y 8 4 / 2 3 . 0<br />
P M _ T A B 1 1 : K E Y 8 4 2 3 . 0 %<br />
P M _ T A B 1 1 : P E D 0 1 2 8 . 9 %<br />
P M _ T A B 1 1 : P E D 0 1 / 2 8 . 9<br />
P M _ T A B 1 1 : P E D 0 1 / 3 4 . 3<br />
P M _ T A B 1 1 : . . . S T O R E . .<br />
P M _ T A B 1 1 : K E Y 0 5 2 0 . 0 %<br />
1 2 Q R S 0 0 : 0 0 V 0 6 3<br />
The last playable KEY on an 80 not system will be<br />
key number 84.<br />
Once the last key is calibrated, press the<br />
“PREVIOUS” button to point the arrow at the key<br />
number.<br />
Rotate the ADJust dial to display “PED01”. If the<br />
system has a sustain pedal solenoid installed the<br />
dampers will begin to repeatedly lift off of the<br />
strings.<br />
Press the “NEXT” button to point the arrow<br />
toward the percentage value.<br />
Rotate the ADJust dial counter clockwise until you<br />
see the dampers hesitate be<strong>for</strong>e lifting.<br />
Rotate the ADJust dial clockwise until the dampers<br />
lift smoothly off of the strings<br />
When finished, press the SELect button to STORE<br />
the new settings to the processor.<br />
The new settings are not saved until<br />
“STORE” is displayed and you are returned<br />
to the TAB11 menu.<br />
Double-Click SEL to exit.<br />
Q R S M U S I C T E C H N O L O G I E S PAGE 33