<strong>3100B</strong> <strong>HFOV</strong><br />
iii<br />
Revision History<br />
Date Revision Changes<br />
January 1993 A Initial Release<br />
January 1996 B Revisions to meet FDA requirements and <strong>3100B</strong> device specification<br />
changes<br />
May 1998 C Performance graphs updated. Performance check procedure updated.<br />
Piston Centering instructions removed. WARNING concerning use in > 28<br />
degrees C added.<br />
October 1998 D Updated addresses & phone numbers. Updated indications for use &<br />
adverse effects. Cautions updated. Added CE mark info. Paw control valve<br />
changed to Pa adjust control valve. Updated treatment strategies. Updated<br />
bias flow, frequency, % inspiratory time and oscillatory pressure amplitude<br />
strategies. Added to non-invasive gas monitoring recommendations.<br />
Updated disease specific variations to general clinical strategies. Updated<br />
suctioning guidelines.<br />
September 1999 E Changed page numbering system. Modified alarm levels adjustment.<br />
Modified Patient Circuit Cal label and instructions. Modified Ventilator<br />
Performance Checks label and instructions. Corrected Mean Pressure<br />
Limit specifications. Removed block diagram. Removed mean pressure<br />
limit instructions. Modified Oscillator subsystems airflow specifications.<br />
Modified WARNING alarms instructions. “Set Max Pa” instructions<br />
updated. Added driver diaphragm lubrication instructions.<br />
January 2001 F Phone numbers corrected. Modified indications for use (removed last<br />
sentence). Modified patient circuit warning. Replaced patient circuit cal.<br />
Label. Updated driver replacement record label. Changed mean pressure<br />
limit to “automatic”. Changed driver replacement hours to 1,500. Updated<br />
figures. Added figure 2.5. Modified figure 3.2. Changed oscillator system<br />
operational life to read “more than 1,00 hours. Changed the lpm values in<br />
chapters 3 and 4. Changed the Warning alarm description. Added low bias<br />
flow note. Modified safety alarms description. Modified figure 4.1.<br />
Removed the words “piston centering” from Mean Pressure Adjust section.<br />
Modified the % Inspiratory Control statement. Modified figure 4.2.<br />
Updated descriptions of “Water Trap Drain Valve” and Hold Down Strap”.<br />
Updated figure 5.3. Updated “start-up” procedure. Changed Maintenance<br />
period to 1,5000 hours. Updated Visual/Audible Alarm table. Updated part<br />
numbers. Updated maintenance procedures for Water Trap, Patient Circuit<br />
and Circuit Calibration. Modified Weaning recommendations.<br />
June 2001 G In Clinical Guidelines Chapter, Changed “Treatment Strategies”,<br />
“Frequency” and “Inspiratory Time” and moved “Mean and Range of<br />
<strong>3100B</strong> Settings”. Modified “General aspects of Clinical Strategy”, added<br />
“Oxygenation” and modified “Weaning” and Ventilation. Added “Summary<br />
of MOAT II Clinical management Strategies” and “Summary of Weaning<br />
Strategy” from MOAT II Clinical Trial. Removed “Summary of <strong>HFOV</strong><br />
Therapeutic Intervention and Rationale”. Modified “Adverse Effects”<br />
September 2001 H Changed 2000 hour Driver Replacement to 1500 hours. Added COPD<br />
and Asthma Caution and Aerosol Warning. Added Inspection of<br />
Diaphragm for Cuts & Tears caution. Modified Indications for Use<br />
statement. Added Chapter 2 Clinical study, re-numbered other chapters.<br />
Simplified manual format to facilitate translation process.<br />
March 2002 J Changed 1500 hour Driver Replacement label and instructions to 4000<br />
hour. Modified list of supplies/replacements. Changed the cooling gas<br />
airflow from 25 lpm to 28 lpm.<br />
767164–101 Rev. R