AT Command Reference - Stollmann
AT Command Reference - Stollmann
AT Command Reference - Stollmann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Stollmann</strong><br />
E+V GmbH<br />
BlueRS+ - SPP<br />
<strong>AT</strong> <strong>Command</strong> <strong>Reference</strong><br />
Value Description<br />
0 Selected by GPIO<br />
1 Set fixed DTE 5<br />
2 Set fixed DCE 6<br />
Note: This command is only applicable for devices that support this feature.<br />
E<br />
Local Echo<br />
<strong>AT</strong> syntax:<br />
<strong>AT</strong>E<br />
This command selects the local echo in command mode.<br />
Param.<br />
<strong>AT</strong>E<br />
<strong>AT</strong>E1<br />
Description<br />
No local echo<br />
Local echo on in command phase<br />
FLASH<br />
Load New Firmware<br />
<strong>AT</strong> syntax:<br />
Configurator syntax:<br />
<strong>AT</strong>**FLASH<br />
flash<br />
This commands loads new firmware into the BlueRS+. The current firmware will be<br />
overwritten. The firmware will be stored in the previously used part of flash memory.<br />
While uploading, the following checks will be performed:<br />
• File transfer protocol is XMODEM 1K<br />
• An overall firmware checksum is used<br />
• The firmware type written in the module header of the firmware must be<br />
compatible with the hardware type and permitted firmware types (stored inside<br />
the bootloader).<br />
For details about the firmware update procedure, see page 48 “Firmware Update”.<br />
Note: This command is only available via the local serial port.<br />
FLC<br />
Flow Control<br />
<strong>AT</strong> syntax:<br />
Configurator syntax:<br />
<strong>AT</strong>**FLC | <strong>AT</strong>**FLC=<br />
flc | flc=<br />
For a description about the settings, see the <strong>AT</strong>&K command (page 10).<br />
5 When using BlueRS+C1/V2, the devmsel=1 (fixed DTE) setting is not supported.<br />
6 When using BlueRS+C1/V2, the devmsel=2 (fixed DCE) setting is not supported.<br />
Author: ta Date of Saving: 18.01.07 Ref: BlueRS+_<strong>AT</strong>_<strong>Command</strong>_<strong>Reference</strong>.doc Revision: 2.02 Page 36 of 54