Electrical Power<br />
www.techrentals.com.au<br />
Cable & Pipe Tracers & Fault Locators<br />
Electrical Testers<br />
PAT Testers & RCD Testers<br />
Micro-Ohm Meters & Earth Testers<br />
Power Analysers, Loggers & Recorders<br />
Current Clamps Probes & Accessories<br />
Insulation Testers & Meggers to 20kV<br />
Oil, Hipot & VLF Testers above 20kV<br />
Circuit Breaker Testers<br />
Transformer Testers<br />
Current Injectors<br />
Protection Relay Testing Systems<br />
AC S<strong>our</strong>ces/Inverters/Generators<br />
Power Transformers & Variacs<br />
Battery Management Systems<br />
Cable & Pipe Tracers<br />
& Fault Locators<br />
See also Ground Penetrating Radar on page 61<br />
See also Underground Services Location on page 61<br />
CScope CATXDSGV-KIT Cable and Pipe Locator<br />
CSC,CATXDSGV-KIT (3730)<br />
AU/MY<br />
Industry standard locator used to determine the exact<br />
location of buried pipes and cables. Functions include:<br />
Power mode for detecting live imbalanced cables to a<br />
depth of 3m. Radio mode for detecting re-radiated radio<br />
signals to a depth of 2m. Generator mode for detecting<br />
conductors carrying the signal generated by the C.Scope<br />
signal generator.<br />
Fluke Cable Locator<br />
FLU,2042 (3602)<br />
AU<br />
Ideal for tracing cables in walls and underground, locating<br />
fuses/breakers on final circuits as well as locating<br />
interruptions and short-circuits in cables and electrical floor<br />
heating systems. Can be used for tracing metallic water and<br />
heating pipes. Supplied as a kit comprising a transmitter<br />
and receiver in a carry case. Voltage measurement range<br />
12 to 400 volts. Frequency range 0 to 60Hz. Transmitter output signal 125kHz.<br />
Transmitter voltage 0 to 400V ac/dc. Depth location 0 to 2.5m. Receiver<br />
voltage detection range 0 to 0.4m. The receiver incorporates a torch for<br />
working in dimly lit locations.<br />
The fi lm symbol indicates there<br />
is a ‘how to video’ online for that<br />
product, see page 1.<br />
Cable & Pipe Tracers<br />
& Fault Locators cont’d.<br />
Megger MPP1002 Cable Fault Pinpoint Locator<br />
MEG,MPP1002-FAULT PP (3603)<br />
A U<br />
Pinpoints faults in shielded and direct buried<br />
primary cables via Geophone probe(s). Can<br />
be used with any surge generator (thumper).<br />
Stand-alone unit measures electromagnetic surge<br />
and supplies the amplitude of that surge which aids in finding the fault. When<br />
fitted with probes the unit will detect the acoustic discharge (thump), measure<br />
the time delay between acoustic and electromagnetic signals and calculate<br />
the distance to fault. Using the dual probe system the direction to fault is<br />
indicated. Detects faults up to 23m away. Battery powered.<br />
Megger TDR20002RM Dual Channel TDR Cable Fault Locator<br />
MEG,TDR2000/2RM (3605)<br />
AU<br />
Time Domain Reflectometer cable fault locator. User selectable ranges from<br />
0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement.<br />
Internal memory for 15 traces. Megger “Tracemaster” software supplied.<br />
RS232 interface for PC communications. High resolution LCD display. Battery<br />
powered. Dust and shower proof to IP54.<br />
Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator<br />
RB,1205T-OSP<br />
MY<br />
Dual input metallic time domain reflectometer cable fault locator for coaxial<br />
cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance<br />
Accuracy: ±0.1ft (0.03m) plus ±.01% of reading. Can store, recall and<br />
download waveform, via RS232 cable. (Viewable with Software.)<br />
Electrical Testers<br />
See also Current Clamps Probes & Accessories on page 31-32<br />
ABB CB-2000<br />
Portable Capacitance Meter<br />
ABB,CB2000 (3500)<br />
AU<br />
Portable (2.4kg) capacitance meter (0 - 1000μF) which<br />
allows individual capacitors in a capacitor bank to be<br />
measured without disconnection. Battery powered with an<br />
ac adapter. Approximately 8 h<strong>our</strong>s operating time between<br />
charges. Supplied software and drivers allow measured<br />
values to be exchanged to and from a PC via supplied USB<br />
cable. Data stored as tab delimited text files.<br />
Hioki 3283 Clamp on Leak HiTester<br />
HIO,3283<br />
MY<br />
Monitor leak current fluctuations. Bandwidth 5Hz to 15kHz.<br />
AC current range 10mA to 200A, resolution 10microA. Accuracy<br />
±1%. LCD display. Battery powered.<br />
Martindale Phase Sequence & Continuity<br />
Indicator 100 to 600V, 50/60Hz<br />
MAR,PSCI424-585 (3502)<br />
AU<br />
Check the presence and sequence of the phases on<br />
3ph circuits. Provides a visual indication of loss of<br />
phase or incorrect sequence. Supplied in 2 forms.<br />
Probe style; the connection to the tester is via 3<br />
insulated cables to 3 fused test probes, 1 with an<br />
insulated crocodile clip. Plug style; a 16A, 4 pin (3ph<br />
& earth, BS4343) plug is fitted to the tester. Use as a<br />
socket tester prior to plugging in 3ph equipment.<br />
24