Industrial Process Calibrators cont’d.<br />
Crystal XP2i 100psi (7 Bar)<br />
NATA with Druck PV411 Hand<br />
Pump<br />
CRY,XP2I CAL KIT 7 (4743)<br />
AU<br />
100psi (7 Bar) pressure gauge and Druck<br />
PV411 hand pump calibration kit. Nata<br />
certified accuracy, ±0.1% of reading<br />
between 20 to 100% of full scale, ±0.02%<br />
of full scale between 0 to 20% of full scale.<br />
Intrinsic and safety ratings registered under<br />
IECEx, ATEX and DNV standards.<br />
Crystal XP2i 5,000psi<br />
(345 Bar) NATA with Druck<br />
PV411 Hand Pump<br />
CRY,XP2I CAL KIT 345 (4765)<br />
AU<br />
5,000psi (345 Bar) pressure gauge and<br />
Druck PV411 hand pump calibration kit. Nata<br />
certified accuracy, ±0.1% of reading between<br />
20 to 100% of full scale, ±0.02% of full scale<br />
between 0 to 20% of full scale. Intrinsic and<br />
safety ratings registered under IECEx, ATEX<br />
and DNV standards.<br />
Druck DPI603 2-NATA 2 Bar Pressure Calibrator<br />
DRU,DPI603-2-NATA (4738)<br />
AU<br />
DRU,DPI603-2<br />
MY<br />
0.075% FS Accuracy includes pump for vacuum and<br />
pressure. Unit will pump up to 2 Bar pressure and<br />
-850mBar vacuum. Measurements can be made to 2 Bar<br />
positive pressure and -1Bar vacuum. The unit has a 24V<br />
energising voltage. Monitors loop current to<br />
55mA DC loop voltage to 50V. Sealed to IP65.<br />
Rechargeable battery operated. Unit can display in 24<br />
different units. BSP 1/8 interface.<br />
Druck DPI603 20 Bar Pressure Calibrator<br />
DRU,DPI603-20<br />
MY<br />
Accuracy 0.075%fs. Pumps up to 20 Bar pressure & -850mBar vacuum.<br />
Measures up to 20 Bar pressure and -1 Bar vacuum. In-built 24V energising<br />
voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface 1/8”<br />
bsp. Battery operated.<br />
Druck DPI104 350 Bar Pressure Calibrator & HTP1 Hydraulic Pump<br />
DRU,DPI104-350<br />
MY<br />
Range 0 to 350 Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV<br />
resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all<br />
@ 0.025% accuracy. S<strong>our</strong>ces 0 to 10V (0.2mV resolution) & 0 to 50mA (1μA<br />
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1%<br />
current 30mA & unregulated supply 24V ±10% current 50mA. Pressure<br />
switch status. Pressure media oil, water & non corrosive gases. Battery<br />
operation 10h or mains operation via charger. Complete with a full range of<br />
pressure connection adaptors.<br />
Druck DPI610-2-NATA 2 Bar Pressure Calibrator<br />
DRU,DPI610-2-NATA (4737)<br />
AU<br />
DRU,DPI610-2<br />
MY<br />
Pneumatic pressure calibrator including pump and<br />
current voltage standard. Pressure range -1 to 2 Bar,<br />
±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%rdg,<br />
±0.004%fs. Temperature -10 to 40°C, ±1 (ambient)<br />
switch open/closed. Voltage output 10VDC, ±0.1% or<br />
24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger stores<br />
up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />
flexible hose kit. Pump includes screw adjustment.<br />
Industrial Process Calibrators cont’d.<br />
Druck DPI610-20-NATA 20 Bar Pressure Calibrator NATA Certification<br />
DRU,DPI610-20-NATA (4751)<br />
AU<br />
DRU,DPI610-20<br />
MY<br />
Pneumatic pressure calibrator including pump and current voltage standard.<br />
Pressure range -1 to 20 Bar ±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10<br />
to 40°C ±1°C (ambient) switch open/closed. Voltage output 10VDC ±0.1%<br />
or 24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger<br />
stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8f,<br />
includes flexible hose kit. Pump includes screw adjustment.<br />
Druck DPI610-400-NATA 400 Bar Pressure Calibrator<br />
DRU,DPI610-400-NATA (4768)<br />
AU<br />
DRU,DPI610-400<br />
MY<br />
Hydraulic pressure calibrator including pump and current voltage standard.<br />
Pressure range 0 to 400 Bar ±0.025%fs. Voltage input 50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to<br />
40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V<br />
±5%. Current output 0 to 24mA, ±0.05% rdg, ±0.01%fs. Data logger stores<br />
up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />
flexible hose kit. Pump includes screw adjustment.<br />
Druck DPI615-20-NATA 20 Bar<br />
Pressure Calibrator<br />
DRU,DPI615-20-NATA (4750)<br />
AU<br />
Pneumatic pressure calibrator including pump and<br />
current voltage standard. Pressure range 0 to 20<br />
Bar ±0.025% FS. Voltage input ±50VDC ±0.05%<br />
rdg ± 0.004% FS. Current input ±55mA ±0.05%rdg<br />
±0.004%FS. Temperature -10 to 40ºC ±1ºC (ambient)<br />
switch open/closed. Voltage output 10VDC ±0.1%<br />
or 24V ±-5%. Current output 0 to 24mA ±0.05%rdg ±0.01%FS. Data logger<br />
stores upto 10,000 values. mA ramp configurable. Pressure port G 1/8 female,<br />
includes flexible hose. Pump includes screw adjustment.<br />
Druck PV411A Multifunction Hand Pump Kit<br />
DRU,PV411A (4789)<br />
AU/MY<br />
Provides up to 700 Bar hydraulic, 40 Bar pneumatic<br />
pressures and vacuum to -950mBar. Built-in stroke adjuster,<br />
lower pressure fine control and tamper proof overpressure<br />
protection.<br />
Druck UPS III-IS Intrinsically Safe Loop Calibrator<br />
DRU,UPS III-IS (4777)<br />
AU<br />
Measure or s<strong>our</strong>ce 0 to 24mA and provide 24V loop<br />
power. 50 VDC measurement and continuity. Accuracy<br />
0.015% of reading, Hart compatible. Dual mA and %<br />
readout, linear or flow. It is an essential tool for loop<br />
testing, instrument maintenance and valve set-up, with<br />
an easy-to-read display and simple-to-use time saving<br />
features.<br />
Emerson Process Management 375 Field Communicator<br />
EME,375 (4795)<br />
MY<br />
Will configure, test, and diagnose y<strong>our</strong> HART® and<br />
Foundation FieldBus devices. Able to communicate with any<br />
device, by any manufacturer. Intrinsically safe. Easy upgrade<br />
over the Internet. Interfaces with AMS PC Suite Software.<br />
Emerson 475 Hart Communicator<br />
EME,475 (4794)<br />
AU/MY<br />
Will configure, test, and diagnose y<strong>our</strong> HART® and<br />
Foundation FieldBus devices. Able to communicate with<br />
any device, by any manufacturer. Intrinsically safe. Easy<br />
upgrade over the Internet. Interfaces with AMS PC Suite<br />
Software.<br />