Construction, Building Services & Survey<br />
www.techrentals.com.au<br />
Air Conditioning & Air Flow<br />
Air Conditioner Valve Balancing<br />
Concrete Testing <strong>Equipment</strong><br />
Underground Services Location<br />
Utility Leak Detection<br />
Ground Penetrating Radar<br />
Pipeline & Cavity Inspection<br />
Material Moisture Meters<br />
Distance Measurement & Surveying<br />
Air Conditioning & Air Flow<br />
Airflow AV2 100mmØ Anemometer NATA Certification<br />
AIR,AV2-NATA (5837)<br />
Specification as above but with NATA certification.<br />
Airflow 36 Pitot Tube<br />
AIR,PITOT-36 (5816)<br />
Pitot tube (36”) for use with manometers and micro manometers.<br />
Alnor EBT-721-A3 Electronic Micromanometer<br />
ALN,EBT-721-A3<br />
MY<br />
Detachable multi-purpose digital manometer that can be used with the<br />
following test and balance tools, such as pitot, air foil, temperature, relative<br />
humidity probes or a 16-point velocity matrix. Differential pressure: ±15 in.<br />
H 2<br />
O, (3735 Pa) 150 in. H 2<br />
O maximum safe operating pressure. Absolute<br />
pressure: 15 to 40 in. Hg (356 to 1016 Hg). Velocity: 25 to 8,000 ft/min (0.125<br />
to 40 m/s) pitot probes; 25 to 5,000 ft/min (0.125 to 25 m/s) air flow probe;<br />
25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity matrix. Volume: 25 to 2,500<br />
ft 3 /m (42 to 4250 m 3 /h) capture hood. RH: 0 to 95% RH (optional probe),<br />
Temperature: -40 to 250°F (-40 to 121°C) probe dependant. Standard comes<br />
with 2ft x 2 ft, upon request additional hood of 2ft x 4 ft and 1ft x 4ft hood would<br />
be provided.<br />
Alnor EBT731 Balometer<br />
Electronic Balancing Tool<br />
ALN,EBT-731<br />
MY<br />
Features a detachable multi-purpose digital<br />
manometer that can be used with the following<br />
test and balance tools, such as pitot, static<br />
pressure probe or a 16-point velocity matrix.<br />
Volume Range: 25 to 2,500 ft cube/min (42<br />
to 4250 m cube/h) with capture hood. Velocity<br />
Range:25 to 2,500 ft/min (0.125 to 12.5 m/s) with velocity matrix. Unit comes<br />
with 2ft x 2ft,2ft x 4ft and 1ft x 4ft hoods.<br />
CSS Portable Smoke Generating Machine<br />
CSS,COLT4 (5890)<br />
AU<br />
Portable smoke generator with variable smoke<br />
emission rate. Suitable for air flow visualisation, HVAC<br />
ductwork leak-testing, fire training and general work.<br />
Pump-free operation with smoke fluid supplied from<br />
consumable aerosol cans. Manual or continuous<br />
operation and off-power facility. Maximum output 31 cubic meters/min at 1.5m<br />
visibility. Operation for 18min from one can at maximum capacity.<br />
Druck DP1705 Manometer 0 to 20kPa<br />
DRU,DPI705 (5808)<br />
AU<br />
Handheld digital manometer range 0 to 20kPa, accuracy 0.2%. Displays all<br />
common engineering units.<br />
AU<br />
AU<br />
Air Conditioning & Air Flow cont’d.<br />
Druck DPI705-IS Manometer 0 to 20kPa<br />
Intrinsically Safe<br />
DRU,DPI705-IS (5809)<br />
AU<br />
Hand held Manometer 0 to 20kPa range. Accuracy 0.2%.<br />
Displays all common engineering units. Intrinsically Safe.<br />
Shortridge ADM-860 Electronic Manometer<br />
SHO,ADM-860 (5812)<br />
AU<br />
Electronic micromanometer for air balance and similar applications. Measures<br />
differential pressure, air velocity and temperature using accessories included.<br />
Differential pressure range 0.0025 to 1500 mm water gauge. Air velocity range<br />
7.5 to 3,000 m/min (750 m/min with velgrid). 100 point memory with sum and<br />
average. Accessories include pitot tube and a 16 point velgrid for face velocity<br />
work including exhaust hoods, clean room outlets, and large filters or coils.<br />
Testo 445 Vane Anemometer with 16mm Vane<br />
TES,445 (5842)<br />
AU<br />
Micro-vane probe. Simultaneous digital display of air<br />
velocity and temperature, with continuous-update, max,<br />
min & mean functions. Volume-flow option with entry<br />
of duct dimensions. Telescope mounted metal probe,<br />
vane 16mmØ. Operating range 0.4 to 60m/s, accuracy<br />
±0.2 m/s, ±1%mv up to 40m/s. Temperature range -30<br />
to <strong>14</strong>0ºC for short-term measurements. Selectable<br />
site-locations, and 3,000 point internal memory for<br />
manual saving or automatic data logging. Battery<br />
powered.<br />
TSI 8324 VelociCalc 100mm<br />
Vane Anemometer<br />
with Volume Display<br />
TSI,8324 (5839)<br />
AU<br />
Vane anemometer with 100mm head,<br />
supplied with handle and 900 mm<br />
articulated telescopic extension. Velocity<br />
measurement range 0.25 to 30m/s ±1%;<br />
temperature measurement range 0 to 80ºC ±0.5 ºC. Volume display range<br />
0 to 4.36 x 106m 3 /h with input for circular or rectangular duct dimensions.<br />
Variable time-constant; sample statistics average, max and min; and “sweep”<br />
mode for extended continuous sampling. Internal memory for single point<br />
measurements or time-based data logging, for up to 2849 samples and 1,000<br />
test IDs, with serial interface, cable and software for data download. Direct<br />
data acquisition [polling] from PC terminal modes. Battery powered with<br />
auto-power-off, and optional AC adaptor.<br />
TSI 8373 Balometer With Logging<br />
TSI,8373 (5826)<br />
AU/MY<br />
Flow range 15 to 1,000l/s (54 to 3,600m 3 /h); accuracy ±5% [to ±2.4l/s].<br />
Operating temperature range 0 to 60°C. Includes 5 hood kit & hard case.<br />
Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />
305 x 1,525mm & 915 x 915mm.<br />
TSI 8375 Accubalance Modular Air Balancing Tool<br />
TSI,8375 (5827)<br />
AU<br />
Balometer with detachable micromanometer (TSI 8710) for air balancing<br />
applications. With 610 x 610mm air capture hood for measurements in the<br />
range 42 to 4250m 3 /h with automatic compensation for barometric pressure<br />
and air temperature, 45cm pitot probe [range 0.13 to 41m/s], 16-point velocity<br />
matrix probe [0.13-13m/s] and static pressure probes [differential pressure<br />
range ±3735Pa with safe limit 37kPa, absolute pressure range 47 to 135kPa.<br />
Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit LCD<br />
display for single or statistical readings with min, max and average of up to<br />
1,000 values of each measured parameter. Manual result storage or automatic<br />
data logging up to 1,000 time/date stamped readings. RS232 port for data<br />
transfer to PC or serial printer, with cable and “LogDat” download software.<br />
Rechargeable with approx 12h operation, or AC adaptor.<br />