Flow Meters for Liquids & Gases<br />
cont’d.<br />
Panametrics PT878E Ultrasonic Liquid Flow Energy Meter<br />
PAN,PT878E (6102)<br />
AU<br />
Portable non-contact liquid flowmeter using transit-time principle.<br />
Includes transducers to measure energy and transducers for pipe 50mm to<br />
2mØ & temperatures -10 to 130°C (various alternative transducers available)<br />
with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically<br />
1%. Data logging for over 100K data points. Outputs analogue 4 to 20mA,<br />
digital (pulse or frequency) and printer/computer (Infrared port). Large LCD<br />
display for velocity, volumetric and energy flow rate, totalised flow and trend<br />
data in alphanumeric and graphical formats. Rechargeable NiMH batteries<br />
and AC power supply/charger.<br />
GE Panametrics PT878 Ultrasonic Liquid Flow Meter<br />
PAN,PT878T (6103)<br />
AU<br />
Portable non-contact liquid flowmeter using transit-time<br />
principle. Includes thickness gauge and transducers for pipe 50mm to<br />
2mØ & temperatures -40 to 130 degC (various alternative transducers<br />
available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s.<br />
Accuracy typically 1%. Data logging for over 100K data points. Analog<br />
inputs compatible with temperature transmitters for energy-flow<br />
calculations. Outputs analog 4 to 20mA, digital (pulse or frequency) and<br />
printer/computer (Infrared port). Large LCD display for velocity, volumetric<br />
and energy flow rate, totalised flow and trend data in alphanumeric and<br />
graphical formats. Rechargeable NiMH batteries and AC power supply/<br />
charger.<br />
GE Panametrics 12 to 50mm Transducers<br />
PAN,C-LP-40NM (6108)<br />
AU//MY<br />
Transducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe 12 to<br />
50mmØ. Complete with CF-LP-50M mounting bracket. Temperature range<br />
-40 to 120°C.<br />
GE Panametrics -20 to 210°C Transducers<br />
PAN,C-PT-10HB (6110)<br />
AU<br />
High temperature transducer pair for PAN,PT868/878 transit-time flowmeter.<br />
Operates on pipe sizes 50mm~2m diameter. Working temperature range<br />
-40~230°C.<br />
GE Panametrics -200 to 400°C Transducers<br />
PAN,OKS (6112)<br />
AU<br />
Very high temperature, wide range transducer pair for PAN,PT868/878<br />
transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to<br />
600mmØ. Uses special clamp system supplied. Appropriate protection and<br />
safe-handling equipment is required for fitting and operation at very high or<br />
low temperatures.<br />
Polysonics Hydra SX30 Dual Frequency Doppler<br />
Liquid Flowmeter<br />
POL,HYDRA-SX30-2 (6132)<br />
AU<br />
Dual frequency doppler ultrasonic non-contact<br />
flowmeter. Velocity range 0.06 to 10m/s, accuracy<br />
±1%. Pipe size range 12 to 5,000mm diameter. Data<br />
logging for 90,000 points, with PC software and<br />
interface cable for download via RS232C interface.<br />
Transducer temperature range -40 to 122°C.<br />
Analogue output 4 to 20mA. Battery operated, 12h<br />
continuous use (8h recharge).<br />
Save y<strong>our</strong> time and reduce<br />
y<strong>our</strong> real costs. Find out all<br />
about <strong>our</strong> Confi guration and<br />
<strong>Download</strong> solutions on page 37.<br />
Combustion, Flue & Industrial<br />
Gas Analysers<br />
See also Environmental Gas & Vap<strong>our</strong> Meters on page 63-64<br />
Novatech O 2<br />
and CO 2<br />
Analyser/Transmitter<br />
NOV,1637-5 (5954)<br />
AU<br />
Oxygen and carbon dioxide analyser for packaging<br />
atmosphere, general industrial and research use.<br />
Oxygen sensor reading 1ppm to 100% with 1%<br />
accuracy. NDIR carbon dioxide analysis 0 to<br />
100% ±3% of full scale. 2 x 4 to 20mA outputs,<br />
1 common & 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow<br />
rate with internal pump 100 to 500cc/min. AC operation.<br />
Testo 335 Combustion Gas Analyser<br />
TES,335 (5913)<br />
AU/MY<br />
Portable industrial flue gas analyser. Determines<br />
temperature (to to 1,000°C), draught/pressure<br />
(±40hPa), oxygen (21%), carbon monoxide<br />
(10,000ppm) and nitric oxide NO (3,000ppm)<br />
concentrations. Calculates carbon dioxide<br />
concentration, efficiency and flue gas loss. Thresholdprotection<br />
of sensors, with 5X autodilution of CO to<br />
50,000ppm. Separate sensor-socket with mini-probe for ambient temperature,<br />
and connection points for compatible differential-pressure devices. Builtin<br />
condensate-trap with warning and auto-switch-off. Internal memory [100<br />
folders X 10 locations X 200 datasets each] for storage of measurementprotocols<br />
and data for printout. Supplied as kit with 335mm probe, cone and<br />
shield-plate, cordless printer and power supply. Rechargeable or AC operation<br />
(alkaline batteries used by printer).<br />
Testo 350XL Portable Flue<br />
Gas Analyser<br />
TES,350XL (5917)<br />
AU<br />
Measures O 2<br />
, CO, CO 2<br />
(measured by NDIR), NO, NO 2<br />
and SO 2<br />
concentrations plus draught, temperature,<br />
excess air, and gross/net efficiency values. Ranges: O 2<br />
0~25% vol, CO 2<br />
0~50%vol, CO with H 2<br />
compensation<br />
0~10,000ppm with measuring-range extension<br />
and selectable dilution factor, NO 0~3,000ppm, NO 2<br />
0~500ppm, SO 2<br />
0~5,000ppm, draught 50hPa, temperature -40~1,000°C. Includes switch-off<br />
and rinse function for CO cell and fresh air rinse for longer term measurements.<br />
Internal memory for 250,000 readings, with RS232C interface and software<br />
provided. Operation from mains or rechargeable battery.<br />
Environmental Test Chambers/<br />
Ovens<br />
Weiss WKL100/40 Temperature & Humidity Chamber<br />
WEI,WKL-100-40 (6218)<br />
AU<br />
Environmental chamber for temperature and humidity<br />
control. -40 to 180°C. Humidity range 10 to 98% (between<br />
10 to 95°C). Max. Heating rate 2.5°C/min Max Cooling<br />
Rate 3.5°C/min. Test space volume 100l 540mm high,<br />
490mm wide & 380mm depth. Programmable touch<br />
screen controller logs actual test temp. and humidity.<br />
Includes Ethernet interface and control software. Single shelf, 50mm access<br />
port with large window to view samples.<br />
Ultrasonic Baths<br />
Soniclean 2000HT Ultrasonic Cleaning Bath<br />
SON,2000HT (6202)<br />
AU<br />
Tank size 495mm W x 295mm D x 299mm H. Includes heater and timer.<br />
50