General Industrial & Process Management<br />

www.techrentals.com.au<br />

Flow Meters for Liquids & Gases<br />

cont’d.<br />

Panametrics PT878E Ultrasonic Liquid Flow Energy Meter<br />

PAN,PT878E (6102)<br />

AU<br />

Portable non-contact liquid flowmeter using transit-time principle.<br />

Includes transducers to measure energy and transducers for pipe 50mm to<br />

2mØ & temperatures -10 to 130°C (various alternative transducers available)<br />

with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically<br />

1%. Data logging for over 100K data points. Outputs analogue 4 to 20mA,<br />

digital (pulse or frequency) and printer/computer (Infrared port). Large LCD<br />

display for velocity, volumetric and energy flow rate, totalised flow and trend<br />

data in alphanumeric and graphical formats. Rechargeable NiMH batteries<br />

and AC power supply/charger.<br />

GE Panametrics PT878 Ultrasonic Liquid Flow Meter<br />

PAN,PT878T (6103)<br />

AU<br />

Portable non-contact liquid flowmeter using transit-time<br />

principle. Includes thickness gauge and transducers for pipe 50mm to<br />

2mØ & temperatures -40 to 130 degC (various alternative transducers<br />

available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s.<br />

Accuracy typically 1%. Data logging for over 100K data points. Analog<br />

inputs compatible with temperature transmitters for energy-flow<br />

calculations. Outputs analog 4 to 20mA, digital (pulse or frequency) and<br />

printer/computer (Infrared port). Large LCD display for velocity, volumetric<br />

and energy flow rate, totalised flow and trend data in alphanumeric and<br />

graphical formats. Rechargeable NiMH batteries and AC power supply/<br />

charger.<br />

GE Panametrics 12 to 50mm Transducers<br />

PAN,C-LP-40NM (6108)<br />

AU//MY<br />

Transducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe 12 to<br />

50mmØ. Complete with CF-LP-50M mounting bracket. Temperature range<br />

-40 to 120°C.<br />

GE Panametrics -20 to 210°C Transducers<br />

PAN,C-PT-10HB (6110)<br />

AU<br />

High temperature transducer pair for PAN,PT868/878 transit-time flowmeter.<br />

Operates on pipe sizes 50mm~2m diameter. Working temperature range<br />

-40~230°C.<br />

GE Panametrics -200 to 400°C Transducers<br />

PAN,OKS (6112)<br />

AU<br />

Very high temperature, wide range transducer pair for PAN,PT868/878<br />

transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to<br />

600mmØ. Uses special clamp system supplied. Appropriate protection and<br />

safe-handling equipment is required for fitting and operation at very high or<br />

low temperatures.<br />

Polysonics Hydra SX30 Dual Frequency Doppler<br />

Liquid Flowmeter<br />

POL,HYDRA-SX30-2 (6132)<br />

AU<br />

Dual frequency doppler ultrasonic non-contact<br />

flowmeter. Velocity range 0.06 to 10m/s, accuracy<br />

±1%. Pipe size range 12 to 5,000mm diameter. Data<br />

logging for 90,000 points, with PC software and<br />

interface cable for download via RS232C interface.<br />

Transducer temperature range -40 to 122°C.<br />

Analogue output 4 to 20mA. Battery operated, 12h<br />

continuous use (8h recharge).<br />

Save y<strong>our</strong> time and reduce<br />

y<strong>our</strong> real costs. Find out all<br />

about <strong>our</strong> Confi guration and<br />

<strong>Download</strong> solutions on page 37.<br />

Combustion, Flue & Industrial<br />

Gas Analysers<br />

See also Environmental Gas & Vap<strong>our</strong> Meters on page 63-64<br />

Novatech O 2<br />

and CO 2<br />

Analyser/Transmitter<br />

NOV,1637-5 (5954)<br />

AU<br />

Oxygen and carbon dioxide analyser for packaging<br />

atmosphere, general industrial and research use.<br />

Oxygen sensor reading 1ppm to 100% with 1%<br />

accuracy. NDIR carbon dioxide analysis 0 to<br />

100% ±3% of full scale. 2 x 4 to 20mA outputs,<br />

1 common & 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow<br />

rate with internal pump 100 to 500cc/min. AC operation.<br />

Testo 335 Combustion Gas Analyser<br />

TES,335 (5913)<br />

AU/MY<br />

Portable industrial flue gas analyser. Determines<br />

temperature (to to 1,000°C), draught/pressure<br />

(±40hPa), oxygen (21%), carbon monoxide<br />

(10,000ppm) and nitric oxide NO (3,000ppm)<br />

concentrations. Calculates carbon dioxide<br />

concentration, efficiency and flue gas loss. Thresholdprotection<br />

of sensors, with 5X autodilution of CO to<br />

50,000ppm. Separate sensor-socket with mini-probe for ambient temperature,<br />

and connection points for compatible differential-pressure devices. Builtin<br />

condensate-trap with warning and auto-switch-off. Internal memory [100<br />

folders X 10 locations X 200 datasets each] for storage of measurementprotocols<br />

and data for printout. Supplied as kit with 335mm probe, cone and<br />

shield-plate, cordless printer and power supply. Rechargeable or AC operation<br />

(alkaline batteries used by printer).<br />

Testo 350XL Portable Flue<br />

Gas Analyser<br />

TES,350XL (5917)<br />

AU<br />

Measures O 2<br />

, CO, CO 2<br />

(measured by NDIR), NO, NO 2<br />

and SO 2<br />

concentrations plus draught, temperature,<br />

excess air, and gross/net efficiency values. Ranges: O 2<br />

0~25% vol, CO 2<br />

0~50%vol, CO with H 2<br />

compensation<br />

0~10,000ppm with measuring-range extension<br />

and selectable dilution factor, NO 0~3,000ppm, NO 2<br />

0~500ppm, SO 2<br />

0~5,000ppm, draught 50hPa, temperature -40~1,000°C. Includes switch-off<br />

and rinse function for CO cell and fresh air rinse for longer term measurements.<br />

Internal memory for 250,000 readings, with RS232C interface and software<br />

provided. Operation from mains or rechargeable battery.<br />

Environmental Test Chambers/<br />

Ovens<br />

Weiss WKL100/40 Temperature & Humidity Chamber<br />

WEI,WKL-100-40 (6218)<br />

AU<br />

Environmental chamber for temperature and humidity<br />

control. -40 to 180°C. Humidity range 10 to 98% (between<br />

10 to 95°C). Max. Heating rate 2.5°C/min Max Cooling<br />

Rate 3.5°C/min. Test space volume 100l 540mm high,<br />

490mm wide & 380mm depth. Programmable touch<br />

screen controller logs actual test temp. and humidity.<br />

Includes Ethernet interface and control software. Single shelf, 50mm access<br />

port with large window to view samples.<br />

Ultrasonic Baths<br />

Soniclean 2000HT Ultrasonic Cleaning Bath<br />

SON,2000HT (6202)<br />

AU<br />

Tank size 495mm W x 295mm D x 299mm H. Includes heater and timer.<br />

50