25.09.2014 Views

Download our Equipment Solutions Brochure (14 MB) - Tech-Rentals

Download our Equipment Solutions Brochure (14 MB) - Tech-Rentals

Download our Equipment Solutions Brochure (14 MB) - Tech-Rentals

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Electrical Power<br />

www.techrentals.com.au<br />

Power Analysers, Loggers<br />

& Recorders cont’d.<br />

CHK GridSense PowerMonic PM40<br />

Power Quality Analyser<br />

CHK,PM40PQA (8708)<br />

AU<br />

Weatherproof IP65 field unit. Channels: 3 Voltage,<br />

63 to 440V (isolated). 4 current 0 to 3,000A (3ph<br />

and neutral) RMS. Supplied with 4 flexible 3,000A<br />

clamp-on CTs (flexible CT length 600mm and Diameter<br />

190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits<br />

LCD display, 7 rows x 20 characters. Records: V, A,<br />

pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics,<br />

voltage and current imbalance (THD and individual to<br />

48th ) and Flicker. Total energy, tariffs, maximum demands, and transient and<br />

sub-cycle disturbances. Included software provides graphs and summaries to<br />

PC. <strong>Download</strong> files while logging USB interface. A PC using Windows 95, 98,<br />

NT4, WIN2000 or XP O/S, is required with the CHK PowerView software to<br />

configure this unit before operating.<br />

CHK GridSense PowerMonic PM45<br />

Power Quality Analyser<br />

CHK,PM45 (8709)<br />

AU<br />

Suitable for low voltage investigations,<br />

power profiling and load studies, harmonic analysis,<br />

power factor studies & flicker and imbalance<br />

monitoring. Features IEC61010 Cat IV 600V safety<br />

certificate, weatherproof IP65 case, 4 channel<br />

voltage and 4 channels current. Supplied with 4 x<br />

Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd<br />

0 to 60VAC, Current input 0 to 3,000A.<br />

Dranetz-BMI Power Guide 4400<br />

DRA-BMI,PG4400 (8715) AU<br />

Provides the full range of<br />

measurements including V, I, W, VA, VAR,<br />

TPF, DPF, demand, energy, harmonics &<br />

inter-harmonics, THD, harmonics spectrum<br />

(V, I, W) to the 63rd, flicker (Pst, Plt), crest<br />

factor, K factor, transformer de-rating etc. Asset comes with AC flexible<br />

current clamp DRA-BMI,RR3035A/24, current range 30/300/3,000A AC only.<br />

Can be extended to different ranges of measurement AC/DC by selecting<br />

appropriate current clamps. Has the full range of arithmetic, vector and<br />

sequence parameters to evaluate distorted and un-balanced loads as defined<br />

in IEEE <strong>14</strong>59. Exceeding high/low limits of any active parameter can trigger<br />

logging. Voltage & current disturbances. DRA-BMI,PG4400 analysers can be<br />

used for power quality measurements, current inrush fault recording long term<br />

monitoring and continuous logging at 1s intervals. DRA-BMI,PG4400 is Class<br />

A compliant with IEC Standard 61000-4-30, AS61000-4-7 and AS61000-4-15.<br />

Dranetz-BMI Power Xplorer PX5<br />

DRA-BMI,PX5 (8716)<br />

AU<br />

Provides the full range of<br />

measurements include V, I, W, VA, VAR, TPF, DPF,<br />

Demand, Energy, Harmonics & Inter-harmonics,<br />

THD, Harmonics spectrum (V, I, W) to the 63rd,<br />

Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/<br />

Avg values are determined in 1/2 cycle RMS steps. Complete with A/C Flexible<br />

Current Clamp DRA-BMI,RR3035A/24, Current Range: 30/300/3,000A AC<br />

only. Can be extended to mentioned different ranges of measurement both<br />

AC/DC by selecting appropriate current clamps. High-speed transient capture<br />

(1MHz sampling rate). Pre-event and post-event waveform capture cycles are<br />

user adjustable. Can be used for power quality measurements, current inrush<br />

(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage<br />

logging), long term monitoring and continuous logging at 1s intervals.<br />

Compliant with IEC Standard 61000-4-30 (Class A), AS61000-4-7 and<br />

AS61000-4-15.<br />

Power Analysers, Loggers<br />

& Recorders cont’d.<br />

Fluke 345 Power Quality<br />

Clamp Meter<br />

FLU,345 (8739)<br />

AU<br />

For measurements on switching loads such as variable frequency<br />

drives, electronic lighting and UPS systems. Low-pass filter and<br />

high EMC immunity design make unit ideal for noisy environments.<br />

600V CAT IV rated, <strong>14</strong>00A AC, 2000A DC. Measure and log<br />

harmonics, inrush current and ripple current on battery systems.<br />

Analyse data and generate reports with included Power Log<br />

software.<br />

Fluke 435 3-Phase<br />

Power Quality & Energy<br />

Analyser<br />

FLU,435 (8738)<br />

AU/MY<br />

Power Quality Analyser to suit a broad range of ac<br />

mains studies. Includes 4 x 600/6000A ac CTs. A<br />

unique energy loss calculator provides the ability to<br />

monetarily quantify energy losses. Supplied with Fluke<br />

Power Log Software for detailed data analysis and report<br />

generation.<br />

Fluke 1735 3-Phase Power Logger<br />

FLU,1735 (8737)<br />

AU/MY<br />

Measures single-phase to 3-phase 4-wire<br />

circuits, 50/60Hz. 3 voltage inputs with common<br />

neutral rated 600Vac (CAT III 600V). 4 current inputs,<br />

4 flexible current probes (15A to 3000A) are included.<br />

Records voltage, current, power (P, Q & S), power factor, frequency, energy<br />

consumption, averaged demand, harmonics (odd up to 25th order), THD<br />

(voltage & current). Includes built-in batteries for up to 12 h<strong>our</strong>s of recording,<br />

and includes Fluke Power Log software.<br />

Fluke VR1710 Single-Phase Voltage<br />

Quality Recorder<br />

FLU,VR1710 (8720)<br />

AU<br />

Single phase power quality analyser. Records RMS,<br />

transients, flicker & harmonics up to the 32nd. Selectable<br />

logging periods from 1s to 20min. Provides continuous<br />

recording with no gaps. Includes software for download,<br />

analysis and automatic reporting.<br />

Hioki 3169-21 Clamp-On<br />

Power HiTester with<br />

4 x 500A CTs<br />

HIO,3169-21 CT500AMP (8726) AU<br />

Measures voltage, current, power,<br />

power factor, harmonics and integrated<br />

values. Simultaneously performs demand<br />

measurements required for power management and energy-saving. Range<br />

0.05A to 500A. Includes 4 x clamp-on CTs. Supplied software provides graphs<br />

and summaries to PC. Flash card data storage. RS232 interface for PC<br />

communications.<br />

Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000A CTs<br />

HIO,3169-21CT1000AMP (8727)<br />

AU<br />

Measures voltage, current, power, power factor, harmonics and<br />

integrated values. Simultaneously performs demand measurements required<br />

for power management and energy-saving. Range 5A to 1000A. Includes 4<br />

x clamp-on CTs. Supplied software provides graphs and summaries to PC.<br />

Flash card data storage. RS232 interface for PC communications.<br />

28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!