General Industrial & Process Management<br />
Pressure & Humidity Transducers<br />
Flow Meters for Liquids & Gases<br />
Druck PTX<strong>14</strong>00-25 25 Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX<strong>14</strong>00-25 (4302)<br />
AU<br />
Output 4 to 20mA output, 0 to 25 Bar input. Requires 9 to 28VDC, supplied<br />
with 12V, 500mA power pack.<br />
Druck PTX <strong>14</strong>00 600 Bar Pressure Transducer<br />
DRU,PTX<strong>14</strong>00-600 (4305)<br />
Output 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.<br />
Pressure Vacuum Gauges/Recorders<br />
Crystal XP2i Digital Logging<br />
Pressure Gauge 7 Bar NATA calibrated<br />
CRY,XP2I-100-NATA (4341)<br />
AU<br />
Range 7 Bar resolution 0.1mBar. Accuracy 1.4 to 7<br />
Bar ±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum<br />
±17.5mBar. Has a 6000 point logging capability. Logging<br />
intervals from 1s up can be set. Logs either actual<br />
pressure, average pressure or average pressure with<br />
max and min. Also logs on demand. 1/4 NPT connector. Intrinsic and safety<br />
ratings registered under IECEx, ATEX and DNV standards.<br />
Crystal XP2i Digital Logging<br />
Pressure Gauge 20 Bar NATA calibrated<br />
CRY,XP2I-300-NATA (4341)<br />
AU<br />
Range 20Bar resolution 1mBar. Accuracy 4 to 20 Bar<br />
±0.1% of reading. 0 to 4Bar ±-4mBar. It Has a 6000<br />
point logging capability. Logging intervals from 1s up can<br />
be set. Logs either actual pressure, average pressure<br />
or average pressure with max and min. Also logs on<br />
demand. Intrinsic and safety ratings registered under<br />
IECEx, ATEX and DNV standards.<br />
Crystal XP2i Digital Logging Pressure Gauge<br />
70 Bar NATA calibrated<br />
CRY,XP2I-1K-NATA (4342)<br />
AU<br />
Range 70Bar resolution 0.001 Bar. Accuracy <strong>14</strong> to 70 Bar ±-0.1% of Reading<br />
0 to <strong>14</strong> Bar ±<strong>14</strong>mBar. Has a 6000 point logging capability. Logging intervals<br />
from 1s up can be set. Logs either actual pressure, average pressure or<br />
average pressure with max and min. Logs on demand. Intrinsic and safety<br />
ratings registered under IECEx, ATEX and DNV standards.<br />
Crystal XP2i Digital Logging Pressure Gauge<br />
210 Bar NATA calibrated<br />
CRY,XP2I-3K-NATA (4343)<br />
AU<br />
CRY,XP2I-3K<br />
MY<br />
Range 210 Bar resolution 0.01Bar. Accuracy 40 to 200 Bar ±-0.1% of reading.<br />
0 to 40 Bar ±-0.04 Bar. Has a 6000 point logging capability. Logging intervals<br />
from 1s up can be set. Logs either actual pressure, average pressure or<br />
average pressure with max and min. Also logs on demand. 1/4 NPT connector.<br />
Intrinsic and safety ratings registered under IECEx, ATEX.<br />
Crystal XP2i Digital Logging Pressure Gauge<br />
700 Bar NATA calibrated<br />
CRY,XP2I-10K-NATA (4344)<br />
AU<br />
CRY,XP2I-10K<br />
MY<br />
Range 700 Bar resolution. 0.01 Bar accuracy. 1% of reading. Has logging<br />
capability. 6000 point pressure logging capability. Logging interval can be<br />
set from 1s up. Logs either Actual Pressure, Average Pressure, or Average<br />
pressure with Max & Min or log on demand. NATA Calibrated. 1/4 inch NPT<br />
connector. Intrinsic and safety ratings registered under IECEx, ATEX and<br />
DNV standards.<br />
AU<br />
See also Environmental Flow Meters on page 69<br />
Flexim Ultrasonic Gas Flow Meter<br />
FLE,G608 (6156)<br />
AU<br />
Ultrasonic flow meter is a clamp-on transit<br />
time gas and liquid flow meter, 2-channel, with Zone 2<br />
Ex-certification for use in hazardous areas. Supplied<br />
with three transducer pairs and a pipe wall thickness<br />
gauge; includes an integral data-logger with more<br />
than 100,000 measured values, easy-to-use software for trending the data<br />
and an integral Lithium-ion rechargeable battery with AC adapter. The GLK<br />
transducers are suitable for 4 to 9mm wall thickness, the GLM 2 to 5mm<br />
and the GSM 2.5mm and greater. Utilises either Shear wave (standard)<br />
transducers, or Lamb wave (specialist gas) transducers. The Lamb wave<br />
transducers resonate the pipe wall to amplify the signal strength, thereby<br />
allowing it to measure applications at significantly lower pressures than the<br />
standard Shear wave transducers.<br />
GE Panametrics PT878GC Ultrasonic Gas Flow Meter<br />
PAN,PT878GC-01 (6151)<br />
AU<br />
Portable non-contact gas flowmeter using transit-time principle. For<br />
operation with ultrasonic transducer-kits (PAN,GC-RL302 & PAN,GC-<br />
RL319) - available separately. Compatible with metal or plastic pipes in the<br />
range 20 to 300mm. Suitable for use with compressed air, natural gas and<br />
other gases. Readout for flow velocity, actual or standard volumetric flow or<br />
mass-flow in numerical or graphic format. Internal logging for 100K flow data<br />
points. Infrared communications port for download to PC or printer interface.<br />
Rechargeable battery for 8h continuous operation.<br />
Gas-flow Small Pipe Transducer Kit for PT878GC<br />
PAN,GC-RL302 (6153)<br />
AU<br />
Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />
flowmeters. Operation at 1MHz for pipes in the range 20 to 55mm typical.<br />
General purpose use for process temperatures -40 to 176°C. Supplied with<br />
two precision gauged clamping fixtures for pipe range.<br />
Gas-flow Medium Pipe Transducer Kit for PT878GC<br />
PAN,GC-RL319 (6155)<br />
AU<br />
Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />
flowmeters. Operation at 500kHz for pipes in the range 75-300mm typical.<br />
General purpose use for process temperatures -40 to 176°C. Supplied with<br />
set of three precision gauged clamping fixtures for pipe range.<br />
GE Panametrics<br />
PT878 Ultrasonic<br />
Flowmeter<br />
PAN,PT878 (6101)<br />
AU/MY<br />
Portable non-contact liquid flowmeter using<br />
transit-time principle. Includes transducers<br />
for pipe 50mm to 2mØ & temperatures -40<br />
to 130°C (various alternative transducers<br />
available) with clamping fixture. Flow velocity<br />
range 0.03 to 12.2m/s. Accuracy typically<br />
1%. Data logging for over 100K data points. Analogue inputs compatible<br />
with temperature transmitters for energy-flow calculations. Outputs analogue<br />
4 to 20mA, digital (pulse or frequency) and printer/computer (Infrared port).<br />
Large LCD display for velocity, volumetric and energy flow rate, totalised flow<br />
and trend data in alphanumeric and graphical formats. Rechargeable NiMH<br />
batteries and AC power supply/charger.<br />
See Also GLO,FP111 Global FP111 Digital Water Velocity Meter on<br />
page 69<br />
49