Construction, Building Services & Survey<br />

Air Conditioning & Air Flow cont’d.<br />

TSI 8386A VelociCalc Air Conditioning Efficiency Meter<br />

TSI,8386A (5848)<br />

AU<br />

Portable efficiency measurement system for HVAC and related<br />

work, with hot wire anemometer, static and differential pressure, temperature<br />

and humidity measurement with heat flow efficiency calculation. Velocity (hot<br />

wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3. Wet<br />

bulb temperature 5 to 60°C. Relative humidity 0 to 95%RH, accuracy ±3%.<br />

Dewpoint -15 to 49°C. Static/differential pressure -1,245 to 3,735Pa, accuracy<br />

±1%. Probe length 100cm, tip diameter 7mm, base diameter 10mm. Includes<br />

data logging and printing. Battery operated.<br />

TSI 8705 DP-CALC Differential Micro-Manometer<br />

TSI,8705 (5815)<br />

AU<br />

Differential micro-manometer measuring differential<br />

pressure, velocity, average, volumetric flow, maximum<br />

and minimum. With static pressure calculations, density<br />

correction and K factor. Pressure range -1245 to 3735Pa.<br />

Velocity range 1.27 to 78.5m/s. Supplied with 200 to 980mm<br />

telescopic pitot tube. Datalogging (1,000 point) with RS232C<br />

interface and software. Battery powered.<br />

TSI 8710 DP-CALC Differential<br />

Micro-Manometer<br />

TSI,8710 (5813)<br />

AU<br />

Micro-manometer for static or differential<br />

pressure, velocity, volumetric flow, atmospheric<br />

pressure and temperature. With statistical<br />

analysis, density correction, K factor and<br />

automatic actual/standard flow calculation.<br />

Differential pressure range ±3735Pa. Velocity display to 41m/s (range depends<br />

on probe). Supplied with static tip, pitot tube, velocity matrix and temperature<br />

probe. Datalogging (1,000 point) with RS232C interface and software.<br />

Rechargeable cells or AC adaptor.<br />

TSI 9535 Anemometer with Logging Capability<br />

TSI,9535 (5845)<br />

AU<br />

Includes data captured download software and USB cable. Logs<br />

velocity and temperature. Will calculate flow rates. 0 to 30m/s Accuracy 3%<br />

of reading or ±015m/sec whichever is greater. Temperature range -18 to 93°C<br />

±0.3°C. Runs 4 x AA batteries.<br />

TSI 9555 Multi-Function Ventilation Meter<br />

TSI,9555<br />

MY<br />

Portable, hand held, multi-function ventilation meter. Comes with differential<br />

pressure and 966 articulate probe which measures air velocity, temperature<br />

and humidity. Calculations include air flow, heat flow, turbulence, wet bulb and<br />

dew point temperature. Velocity measurement: Range: 0 to 9,999 ft/min (0 to<br />

50 m/s) , Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s), Resolution: 1 ft/<br />

min (0.01 m/s). Temperature measurement: Range: <strong>14</strong> to <strong>14</strong>0°F (-10 to 60°C),<br />

Accuracy: ±0.5°F (±0.3°C), Resolution: 0.1°F (0.1°C). Humidity measurement:<br />

Range: 0 to 95% RH, Accuracy: ±3% RH, Resolution: 0.1% RH.<br />

TSI 9565A VelociCalc Air Conditioning Efficiency Meter<br />

TSI,9565A (5849)<br />

AU<br />

Portable efficiency measurement system for HVAC and related<br />

work, with hot wire anemometer, static and differential pressure, temperature<br />

and humidity measurement with heat flow efficiency calculation. Velocity (hot<br />

wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3.<br />

Wet bulb temperature 5 to 60°C. Relative humidity 0~95%RH, accuracy ±3%.<br />

Dewpoint -15 to 49°C. Static/differential pressure -3,735 to 3,735Pa, accuracy<br />

±1%. Probe length 1m, tip diameter 7mm, base diameter 10mm. Includes data<br />

logging and printing. Battery operated. USB & Bluetooth download.<br />

Air Conditioning & Air Flow cont’d.<br />

Vaisala WAA151 Wind Speed/Direction Transducer<br />

VAI,WAA151 (5886)<br />

AU<br />

Range 0.4 to 75m/s. Current output with selectable ranges including 4 to<br />

20mA & 0 to 20mA. Requires indicator module such as DE,DT600 datalogger<br />

for indication of wind speed and direction.<br />

Air Conditioner Valve Balancing<br />

See also Data Loggers: Testo Temperature & Humidity Loggers<br />

on page 48<br />

T<strong>our</strong> & Anderson Scope Balancing Meter 1000kpa<br />

TA,CBI<br />

MY<br />

Digital pressure balancing instrument with LCD display.<br />

For cooling water valve balancing in air conditioning plants and similar<br />

applications. Firmware revision 3A. Includes facility for entry of Kv value to<br />

allow balancing of all hydronic valve types. Differential pressure range -0.5 to<br />

20.5m water gauge at a total pressure of less than 200m. Resolution 0.001m.<br />

Flow resolution 0.001l/s. Battery operated.<br />

T<strong>our</strong> & Anderson Scope Balancing Meter<br />

1000kpa<br />

TA,SCOPE (5801)<br />

AU<br />

Digital flow balancing instrument with color<br />

display. For cooling water valve balancing in<br />

air conditioning plants and similar applications.<br />

Includes facility for entry of Kv value to allow<br />

balancing of all hydronic valve types. Differential<br />

pressure range -0.5 to 20.5m water gauge at a total<br />

pressure of less than 200m. Resolution 0.001m.<br />

Flow resolution 0.001l/s. Battery operated.<br />

TSI TA465A Multi-Function<br />

Ventilation Meter<br />

TSI,TA465A<br />

MY<br />

Portable, hand held, Multi-Function Ventilation Test<br />

Instruments. It comes with differential pressure. It also<br />

comes with the 966 articulate probe which measures air<br />

velocity, temperature and humidity. Calculations include<br />

air flow, heat flow, turbulence, wet bulb and dew point<br />

temperature. Velocity Measurement Range: 0 to 9,999 ft/min (0 to 50 m/s)<br />

Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s) Resolution: 1 ft/min (0.01<br />

m/s) Temperature Measurement Range: <strong>14</strong> to <strong>14</strong>0°F (-10 to 60°C) Accuracy:<br />

±0.5°F (±0.3°C) Resolution: 0.1°F (0.1°C) Humidity Measurement Range: 0 to<br />

95% RH Accuracy: ±3% RH Resolution: 0.1% RH.<br />

Concrete Testing <strong>Equipment</strong><br />

See also Endoscopes, Borescopes & Visual Inspection on page 41<br />

See also Ground Penetrating Radars on page 61<br />

See also Pipeline & Cavity Inspection on page 61-62<br />

Elcometer 331-B Basic Cover Meter<br />

ELC,331-B (4924)<br />

AU/MY<br />

Displays depth and orientation of the reo bars.<br />

Deep search head supplied. 40mm diameter<br />

bar depth 35 to 180mm depth, 8mm diameter bar<br />

depth 25 to 160mm depth. Rechargeable battery<br />

allows 32h of continuous operation (20h with<br />

backlight).<br />