2.5.1 Direct Tallies<br />

These are tallies coupled directly to a UMD or Tally LED panel. They may be derived, for example, from the<br />

parallel closures from a Vision Mixer via the D37 connector on the System Controller.<br />

There is the capability of lighting the left and right tallies on the UMD from separate tally signals – i.e. split<br />

tallies.<br />

Split Tallies<br />

To set Direct Tallies<br />

• Highlight the required Display.<br />

• Enter in the left lower box the left tally assignment. The right tally assignment is filled automatically when<br />

the OK button is pressed.<br />

• If a split tally arrangement is required, enter the tally number before selecting the OK button.<br />

• Map any Tally Lamps on the Desktop (the hardware being LEDs on panels) to the appropriate Tally<br />

Output by RH Mouse clicking on the Tally Lamp on the Desktop. The actual LED will have to be hardwired<br />

to the appropriate D37 Tally Output connector.<br />

» Direct tallies may also be entered by selecting the Display on the Desktop with the RH mouse button<br />

and then selecting Set Direct Tally from the menu.<br />

» Direct tallies have preference over router-associated tallies. This means that a UMD that has a direct<br />

tally mapped to it which may be OFF, will not show a tally LED lit even if a live router-associated tally<br />

is also mapped to that UMD.<br />

The right tally must always have a tally number entered. It is not possible to assign only a left tally to a UMD.<br />

If a RH tally is not required it may be disabled via the following procedure.<br />