RED-D-ARC DC-600
RED-D-ARC DC-600
RED-D-ARC DC-600
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
B-3<br />
WELDING CAPABILITY<br />
OPERATION<br />
B-3<br />
The <strong>DC</strong>-<strong>600</strong> has the following Output and Duty Cycle based on operation for a 10 minute period:<br />
<strong>600</strong> Amps, 44 Volts at 100%<br />
680 Amps, 44 Volts at 60%<br />
750 Amps, 44 Volts at 50%<br />
MEANINGS OF GRAPHICAL SYMBOLS ON CASE FRONT<br />
Input POWER ON/OFF Switch<br />
LOCAL/REMOTE Switch<br />
SYMBOL<br />
MEANING<br />
SYMBOL<br />
MEANING<br />
ON<br />
Control Of Output Voltage and<br />
Current is Via <strong>DC</strong>-<strong>600</strong>'s Control Dial<br />
OFF<br />
Remote Control of Output Voltage<br />
and Current<br />
Pilot Light<br />
OUTPUT CONTROL<br />
INPUT POWER<br />
Input power on when light is illuminated<br />
(except for abnormal conditions).<br />
Always indicates POWER ON/OFF<br />
switch is in ON position.<br />
MODE Switch<br />
CC STICK: Shielded Metal Arc<br />
Welding (SMAW), this switch<br />
position is also used for Air<br />
Carbon Arc Cutting (AAC)<br />
CV SUBMERGED <strong>ARC</strong>:<br />
Constant Voltage Submerged<br />
Arc Welding (SAW)<br />
CV INNERSHIELD: Flux Cored<br />
Arc Welding (FCAW), this switch<br />
position is also used for Gas<br />
Metal Arc Welding (GMAW).<br />
OUTPUT VOLTAGE<br />
AND CURRENT<br />
Clockwise Increase of Output<br />
Voltage and Current<br />
Output Terminal Connections<br />
Positive Output Terminal<br />
Negative Output Terminal<br />
TERMINALS ON/REMOTE Switch<br />
OUTPUT TERMINALS<br />
ENERGIZED<br />
Remote Control of Output Terminals<br />
(Energized or Non-Energized)<br />
WARNING Identification<br />
Circuit Breaker<br />
Warning and Caution Identification<br />
Circuit Breaker (two breakers: 15A<br />
for 115V circuit and 10A for 42V<br />
circuit)<br />
<strong>DC</strong>-<strong>600</strong>