F-3<br />
DIAGRAMS<br />
F-3<br />
CONNECTION OF LN-7 TO THE CV-655, <strong>DC</strong>-655 OR <strong>DC</strong>-<strong>600</strong> POWER SOURCE<br />
14-PIN<br />
RECEPTACLE<br />
POWER SOURCE<br />
CONTROL CABLE<br />
FOR CONTROL CABLE<br />
WITH 14 PIN MS-TYPE<br />
PLUG CONNECTOR<br />
Do not operate with covers removed.<br />
Disconnect power source before<br />
servicing.<br />
21<br />
LN-7 TO INPUT<br />
CABLE PLUG<br />
LN-7 CONTROL<br />
CABLE<br />
OR<br />
FOR CONTROL CABLE<br />
WITH TERMINAL STRIP<br />
LEAD CONNECTORS<br />
Do not touch electrically live parts.<br />
Only qualified persons should install, use or<br />
service this machine.<br />
+21<br />
-<br />
N.F.<br />
21<br />
41 4 2 31 32 75 76 77<br />
N.B. & N.C.<br />
NEGATIVE POSITIVE<br />
N.D.<br />
N.E.<br />
32<br />
31<br />
2<br />
4<br />
GND<br />
21<br />
N.A. Welding cables must be of proper capacity for the current and<br />
duty cycle of immediate and future applications. See LN-7<br />
Operating Manual for proper sizes.<br />
N.B. If LN-7 is equipped with a meter kit, extend LN-7 control cable<br />
lead #21 from control cable with terminal strip connectors or from<br />
14-pin receptacle using #14 AWG or larger insulated wire physically<br />
suitable for the installation. An S16586-[LENGTH] remote<br />
voltage sensing work lead may be ordered for this purpose.<br />
Connect it directly to the work piece independent of the welding<br />
work cable connection. For convenience, this extended #21 lead<br />
should be taped to the welding work lead. (If the length of<br />
welding work cable is short, less than 25 feet, and connections<br />
can be expected to be reliable, then control cable lead #21 does<br />
not need to be extended and can be directly connected to<br />
terminal #21 on the terminal strip. Note that this is not the<br />
preferred connection because it adds error to the LN-7 voltmeter<br />
reading.)<br />
N.G.<br />
N.C. Tape up bolted connection if lead #21 is extended.<br />
ELECTRODE CABLE<br />
TO WIRE FEED UNIT<br />
N.A.<br />
N.D. Connect the control cable ground lead to the frame terminal<br />
marked near the power source terminal strip. The power<br />
source grounding terminal (marked and located near the power<br />
source input power connections) must be properly connected to<br />
electrical ground per the power source operating manual.<br />
TO WORK<br />
N.E. If an optional remote voltage control is used, connect it to<br />
this terminal strip.<br />
REMOTE VOLTAGE SENSING LEAD<br />
Above diagram shows electrode connected positive. To change polarity,<br />
turn power off, reverse the electrode and work leads at the power<br />
source and position the switch on wire feeder (if equipped )<br />
to proper polarity. Also refer to note N.F.<br />
N.F. If lead #21 is to be connected to the terminal strip,<br />
connect to the #21 terminal that matches work polarity. This<br />
connection must be changed whenever the electrode polarity is<br />
changed.<br />
N.G. Illustration does not necessarily represent actual position of<br />
appropriate output studs. Refer to power source operating manual<br />
for more information.<br />
For proper setting of switches on power source,<br />
see power source operating manual.<br />
10-30-98F<br />
S22976<br />
<strong>DC</strong>-<strong>600</strong>