DSTO-RR-0208<br />

Figure 11: <str<strong>on</strong>g>The</str<strong>on</strong>g> effect <str<strong>on</strong>g>of</str<strong>on</strong>g> different peening variables <strong>on</strong> surface finish, Top- over-pressure or excessive<br />

time, Bottom left- nozzle angle and Bottom right- even indentati<strong>on</strong>s but numerous surface<br />

cuts from debris.<br />

Aircraft are subject to spectrum loading and <strong>the</strong>re is <strong>the</strong> potential (a) for a high spectrum<br />

loads to change <strong>the</strong> beneficial residual stresses in <strong>the</strong> comp<strong>on</strong>ent and (b) for different fatigue<br />

lives as a result <str<strong>on</strong>g>of</str<strong>on</strong>g> a changed balance between crack initiati<strong>on</strong> and crack growth. Clark and<br />

Clayt<strong>on</strong> (1991) examined <strong>the</strong> effect <str<strong>on</strong>g>of</str<strong>on</strong>g> c<strong>on</strong>stant amplitude and spectrum loading <strong>on</strong> <strong>the</strong><br />

fatigue life <str<strong>on</strong>g>of</str<strong>on</strong>g> peened comp<strong>on</strong>ents, using small numbers <str<strong>on</strong>g>of</str<strong>on</strong>g> specimens, at different overall<br />

stress levels. A more detailed test program examining <strong>the</strong> effect <strong>on</strong> fatigue life <str<strong>on</strong>g>of</str<strong>on</strong>g> peening<br />

treatment under spectrum loading was carried out at AMRL (Sharp, Clayt<strong>on</strong> and Clark,<br />

1993). <str<strong>on</strong>g>The</str<strong>on</strong>g> test results, Figure 12, clearly show that at <strong>the</strong> high stress (low cycle) end <str<strong>on</strong>g>of</str<strong>on</strong>g> <strong>the</strong><br />

fatigue curve, shot peening can be detrimental to fatigue life. At <strong>the</strong> low stress (high cycle)<br />

end <str<strong>on</strong>g>of</str<strong>on</strong>g> <strong>the</strong> fatigue curve, shot peening is beneficial to fatigue life but <strong>the</strong> amount <str<strong>on</strong>g>of</str<strong>on</strong>g> benefit is<br />

c<strong>on</strong>trolled by <strong>the</strong> peening process quality.<br />