Product Description<br />
Self Test Mode<br />
TYPICAL SCREEN DISPLAYS<br />
These are some samples of typical screens you will see while cutting. If<br />
the LCTHC <strong>and</strong> your Z is working properly you will not see major deviation<br />
in the difference between the TipV <strong>and</strong> SetV.<br />
TipV: 141<br />
SetV: 143<br />
<strong>Torch</strong> Fired. Tip Voltage is 141VDC (your value may vary)<br />
ARC OK is ON (Valid)<br />
LCTHC is sending an UP signal<br />
To MACH to raise Z<br />
TipV: 148<br />
SetV: 143<br />
TOR<br />
ARC<br />
TOR<br />
ARC<br />
T<br />
S<br />
<strong>Torch</strong> Fired. Tip Voltage is 148VDC (your value may vary)<br />
ARC OK is ON (Valid)<br />
TIP SAVER is ACTIVE<br />
LCTHC is NOT sending DOWN signal<br />
To MACH to lower Z<br />
TIP SAVER MAY flash on <strong>and</strong> off during cutting especially at<br />
the end of a cut. This is normal. NOTE Tip Saver must be ON in<br />
the settings for this feature to work<br />
IMPORTANT!<br />
UP Arrow<br />
should show up<br />
in MACH<br />
Screen <strong>and</strong> Z<br />
should move<br />
UP<br />
TIPS<br />
You can change<br />
the SETV value<br />
while cutting to fine<br />
tune the cut gap.<br />
Normally a volt or<br />
two is all it takes<br />
TipV: 141<br />
SetV: 141<br />
TOR<br />
ARC<br />
You MUST have<br />
ARC OK for the<br />
LCTHC to function.<br />
Lack of ARC OK<br />
will cause the UP<br />
<strong>and</strong> DOWN to NOT<br />
function since the<br />
LCTHC considers<br />
the absence of<br />
ARC OF to indicate<br />
the torch is not ON.<br />
Page 15