PC w/MACH3<br />

Grounding practices to reduce noise <strong>and</strong> increase safety<br />

MP3000-DTHC Interface/<strong>Control</strong> Box<br />

Note THC Sensor Card shielded cable<br />

is not connected to any ground in the <strong>Control</strong> box<br />

Do NOT Ground PC or <strong>Control</strong>lers to<br />

Earth Ground Rod. Conrollers will reference themselves<br />

to power ground through their AC lines<br />

<strong>Control</strong>ler Cabinet<br />

MP3000 <strong>and</strong> UBOB have built in isolation on all inputs from the table<br />

to prevent noise transfer <strong>and</strong> ground loops<br />

THC Sensor Card<br />

CNC PLASMA TABLE<br />

Use ground strap to gantry from table<br />

Tabel I/O<br />

Card<br />

(limits, home<br />

Aux relay)<br />

PLASMA<br />

UNIT<br />

Attached to metal<br />

Chassi<br />

#10 to #4 Ga heavy wire<br />

Gantry<br />

Ground Rod or Metal pole<br />

in earth ground<br />

Ground runs should<br />

be less than 10’<br />

Grounding plate<br />

#10 to #4 Ga heavy wire<br />