Stenner Peristaltic Chemical Feed Pumps<br />
Patented Mechanical Control<br />
Stenner’s unique control mechanism allows<br />
the pump’s output to be scaled from 5% to<br />
100% with the simple turn of a dial. This<br />
eliminates the need for troublesome<br />
electronic timers.<br />
High Pressure Handling<br />
Stenner manufactures the only high<br />
pressure peristaltic metering pump that can<br />
operate reliably and consistently against<br />
pressure of up to 100 PSI.<br />
Safe and Versatile<br />
Chemicals are metered without exposure to<br />
air or to moving mechanical parts. Undiluted<br />
muriatic acid and chlorine can be pumped<br />
without harm to the system. Since no<br />
hydraulic fluids are used, there is no<br />
possible leakage to the chemicals being<br />
metered.<br />
Peristaltic Advantage<br />
Peristalsis occurs when the rotation of the<br />
rollers around the inside diameter of the<br />
tube housing compresses and dilates the<br />
pumping tube. This eliminates diaphragms<br />
or foot valves while allowing the system to<br />
be completely self-priming. Hydrogen<br />
Peroxide can be pumped without concern<br />
about vapor lock.<br />
Practical Modular Design<br />
All major feeder components are secured<br />
by stainless steel locking rivets for quick<br />
disassembly without tools. This also makes<br />
adding capacity a snap.<br />
Easy Tube Maintenance<br />
Pumping tubes are easily replaced. Just set<br />
the tube in place and let it thread itself into<br />
position. Down time and maintenance costs<br />
are kept to a minimum through periodic tube<br />
replacement.<br />
SVP Series (left) & Classic Series (above)<br />
Features<br />
• Precision pumping of fluids up to 170 gallons per day<br />
• Completely self-priming, can operate dry<br />
• Will not clog from dirt and minor debris<br />
• Will not lose prime from air bubbles or hydrogen peroxide<br />
gassing<br />
• Can pump against pressure of up to 100 PSI (maximum GPD 34)<br />
• Check valves not required under 25 PSI<br />
• Accurate within 2% of listed outputs<br />
• Safer to use: chemicals are not exposed to air or to moving<br />
parts<br />
• Five interchangeable tube sizes for control of feeder output<br />
• Tube lubrication is not required<br />
• Vertical or horizontal mount<br />
Applications<br />
• Biocide<br />
• Pools & Spas<br />
• Sewage Treatment • Cooling Towers<br />
• Boiler Treatment • Irrigation<br />
• Food Service<br />
• Metal Plating<br />
• Private & Municipal Water Systems<br />
• Poultry Farming & Processing<br />