OFF<br />

ON<br />

<strong>TCAEY</strong>-<strong>THAEY</strong> 245÷265<br />

dimensions and footprints<br />

<strong>TCAEY</strong> – <strong>THAEY</strong> 238 installation dimensions and footprints<br />

b<br />

c<br />

14<br />

2 3<br />

4<br />

1<br />

15 15<br />

a<br />

d<br />

4<br />

e<br />

f<br />

9<br />

8<br />

11<br />

5 7<br />

10<br />

6<br />

13<br />

12<br />

16<br />

g h 16 i h l m n<br />

Model a b c d e f g h i l m n<br />

238 mm 1565 1070 2315 75 195 233 385 28 942 544 1562 160<br />

1. Control panel;<br />

2. Isolat or;<br />

3. Electrical board;<br />

4. Compressor;<br />

5. Water inlet;<br />

6. Water outlet;<br />

7. Pressure gauge<br />

8. Power suppl y inl et;<br />

9. Pump housi ng (ASDP1/ ASDP2 inst allation);<br />

10. Pump housi ng (P1/P2 – ASP1/ ASP2 ins tallations);<br />

11. Water buffer tank (ASP1/ASP2 – ASDP1/ASD P2 ins tallati ons);<br />

12. Expansion tank;<br />

13. Sys tem wat er drain;<br />

14. Fan;<br />

15. Finned coil;<br />

16. Anti-vi bration support (KSA acc essor y).<br />

Installation<br />

○ The unit is designed for outdoor inst allation.<br />

○ The unit is equipped wit h male threaded water connections.<br />

○ The unit must be positioned to c ompl y with the mi nimum<br />

recommended cl earances, bearing in mind the acc ess t o wat er and<br />

electrical connections .<br />

○ The unit c an be equipped wit h anti- vibration mountings on request<br />

(KSA).<br />

○ We recommend installing isolating valves that isolate the unit from<br />

the res t of the s yst em.<br />

○ It is ess ential to fit a metal mes h filter (squar e mesh of no greater<br />

than 0. 8 mm) on the unit ret urn piping.<br />

○ The unit may not be inst alled on brac kets or shel ves.<br />

○ Correct installation and positioning includes levelling the unit on a<br />

surface c apable of bearing its weight.<br />

L4<br />

Clearances and positioning<br />

L1<br />

L3<br />

Model 238<br />

L1 mm 800<br />

L2 mm 800<br />

L3 mm 1000<br />

L4 mm 800<br />

Movement<br />

○ Movement of the unit shoul d be performed wit h car e, in order to<br />

avoid damage to the ext ernal s tructur e and to t he inter nal mec hanic al<br />

and electrical c omponents.<br />

○ Do not stack the units.<br />

○ The t emperature li mits for s torage are -9°÷45°C.<br />

L2<br />

Weights<br />

Model 238<br />

<strong>TCAEY</strong> kg 560<br />

<strong>THAEY</strong> kg 580<br />

<strong>TCAEY</strong> P1-P2 kg 580<br />

<strong>THAEY</strong> P1-P2 kg 600<br />

<strong>TCAEY</strong> ASP1- ASP2 kg 625<br />

<strong>THAEY</strong> ASP1- ASP2 kg 645<br />

The weights refer t o pac kaged units without water<br />