TCAEY-THAEY 115÷238 - Rhoss
TCAEY-THAEY 115÷238 - Rhoss
TCAEY-THAEY 115÷238 - Rhoss
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
OFF<br />
ON<br />
<strong>TCAEY</strong>-<strong>THAEY</strong> 245÷265<br />
dimensions and footprints<br />
<strong>TCAEY</strong> – <strong>THAEY</strong> 238 installation dimensions and footprints<br />
b<br />
c<br />
14<br />
2 3<br />
4<br />
1<br />
15 15<br />
a<br />
d<br />
4<br />
e<br />
f<br />
9<br />
8<br />
11<br />
5 7<br />
10<br />
6<br />
13<br />
12<br />
16<br />
g h 16 i h l m n<br />
Model a b c d e f g h i l m n<br />
238 mm 1565 1070 2315 75 195 233 385 28 942 544 1562 160<br />
1. Control panel;<br />
2. Isolat or;<br />
3. Electrical board;<br />
4. Compressor;<br />
5. Water inlet;<br />
6. Water outlet;<br />
7. Pressure gauge<br />
8. Power suppl y inl et;<br />
9. Pump housi ng (ASDP1/ ASDP2 inst allation);<br />
10. Pump housi ng (P1/P2 – ASP1/ ASP2 ins tallations);<br />
11. Water buffer tank (ASP1/ASP2 – ASDP1/ASD P2 ins tallati ons);<br />
12. Expansion tank;<br />
13. Sys tem wat er drain;<br />
14. Fan;<br />
15. Finned coil;<br />
16. Anti-vi bration support (KSA acc essor y).<br />
Installation<br />
○ The unit is designed for outdoor inst allation.<br />
○ The unit is equipped wit h male threaded water connections.<br />
○ The unit must be positioned to c ompl y with the mi nimum<br />
recommended cl earances, bearing in mind the acc ess t o wat er and<br />
electrical connections .<br />
○ The unit c an be equipped wit h anti- vibration mountings on request<br />
(KSA).<br />
○ We recommend installing isolating valves that isolate the unit from<br />
the res t of the s yst em.<br />
○ It is ess ential to fit a metal mes h filter (squar e mesh of no greater<br />
than 0. 8 mm) on the unit ret urn piping.<br />
○ The unit may not be inst alled on brac kets or shel ves.<br />
○ Correct installation and positioning includes levelling the unit on a<br />
surface c apable of bearing its weight.<br />
L4<br />
Clearances and positioning<br />
L1<br />
L3<br />
Model 238<br />
L1 mm 800<br />
L2 mm 800<br />
L3 mm 1000<br />
L4 mm 800<br />
Movement<br />
○ Movement of the unit shoul d be performed wit h car e, in order to<br />
avoid damage to the ext ernal s tructur e and to t he inter nal mec hanic al<br />
and electrical c omponents.<br />
○ Do not stack the units.<br />
○ The t emperature li mits for s torage are -9°÷45°C.<br />
L2<br />
Weights<br />
Model 238<br />
<strong>TCAEY</strong> kg 560<br />
<strong>THAEY</strong> kg 580<br />
<strong>TCAEY</strong> P1-P2 kg 580<br />
<strong>THAEY</strong> P1-P2 kg 600<br />
<strong>TCAEY</strong> ASP1- ASP2 kg 625<br />
<strong>THAEY</strong> ASP1- ASP2 kg 645<br />
The weights refer t o pac kaged units without water<br />
45