09.11.2014 Views

TCAEY-THAEY 115÷238 - Rhoss

TCAEY-THAEY 115÷238 - Rhoss

TCAEY-THAEY 115÷238 - Rhoss

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

0 OFF<br />

I ON<br />

TXAEY 117÷130<br />

dimensions and footprints<br />

TXAEY 117÷130 dimensions and footprints, P1 installation<br />

o<br />

p<br />

a<br />

c<br />

6<br />

2<br />

3<br />

1<br />

8<br />

11<br />

12 11<br />

6<br />

4<br />

e<br />

10<br />

9<br />

n<br />

m<br />

13 14<br />

15 16<br />

17<br />

5<br />

i<br />

l<br />

i<br />

7 b<br />

7<br />

f<br />

d g h<br />

g<br />

Model a b c d e f g h i l m n o p<br />

117 mm 1490 1522 500 580 1090 60 20 1448 82 340 150 160 60 100<br />

124 mm 1490 1522 500 600 1280 60 20 1448 82 340 150 160 60 100<br />

130 mm 1790 1822 600 695 1510 60 20 1748 82 440 150 160 60 100<br />

1. Control panel;<br />

2. Isolat or;<br />

3. Electrical board;<br />

4. Compressor;<br />

5. Pump;<br />

6. Fan;<br />

7. Anti-vi bration support (KSA acc essor y);<br />

8. Coil;<br />

9. Protecti on mes h (KRP access ory);<br />

10. Expansion vessel;<br />

11. Power suppl y inl et;<br />

12. Pressure gauge<br />

13. Primar y wat er outlet;<br />

14. Recover y water outlet;<br />

15. Primar y water inlet;<br />

16. Recover y water inlet;<br />

17. Condensation drain.<br />

Installation<br />

○ The unit is designed for outdoor inst allation.<br />

○ The unit is equipped wit h male threaded water connections.<br />

○ The unit must be positioned to c ompl y with the mi nimum<br />

recommended cl earances, bearing in mind the acc ess t o wat er and<br />

electrical connections .<br />

○ The unit c an be equipped wit h anti- vibration mountings on request<br />

(KSA).<br />

○ We recommend installing intercept valves that isolate the unit fr om<br />

the res t of the s yst em.<br />

○ It is ess ential to fit a metal mes h filter (squar e mesh of no greater<br />

than 0. 8 mm) on the unit ret urn piping.<br />

○ The unit may not be inst alled on brac kets or shel ves.<br />

○ Correct installation and positioning includes levelling the unit on a<br />

surface c apable of bearing its weight.<br />

L4<br />

Clearances and positioning<br />

L3<br />

L1<br />

Model 117 124 130<br />

L1 mm 300 300 400<br />

L2 mm 600 600 600<br />

L3 mm with open outlet<br />

L4 mm 300 300 300<br />

Movement<br />

○ The unit s houl d be handled with c are, in order to avoi d damage t o<br />

the exter nal struc ture and t o t he internal mechanical and el ectrical<br />

components.<br />

○ Do not stack the units.<br />

○ The t emperature li mits for s torage are -9° ÷45°C.<br />

L2<br />

Weights<br />

Model 117 124 130<br />

TXAEY kg 220 280 370<br />

The weights refer t o pac kaged units without water.<br />

The weight of t he full unit is obt ained by adding t o t he weight of the tank<br />

wat er contents, i ndicated in t abl e “A”.<br />