09.11.2014 Views

TCAEY-THAEY 115÷238 - Rhoss

TCAEY-THAEY 115÷238 - Rhoss

TCAEY-THAEY 115÷238 - Rhoss

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TCAEY</strong>-<strong>THAEY</strong> 115÷238<br />

general characteristics<br />

New Compact-Y series<br />

Energy-saving, reliable and versatile water chillers and<br />

heat pumps<br />

A comp lete, flexible ser ies<br />

Nine new water chillers and heat pumps from 15 to 38 kW in R410A,<br />

which can be fitt ed wit h t he i nnovati ve AdaptiveFunction Plus control<br />

logic developed by RHOSS S.p.A. in partnership wit h t he U niversity of<br />

Padua, to obtain optimal comfort levels in all wor king conditions and the<br />

best possibl e performanc e in ter ms of energy efficienc y during seas onal<br />

operation.<br />

AdaptiveFunction Plu s provi des a comf ort and energy s aving<br />

guarant ee!<br />

LOW ENERGY CONSUMPTION water chillers and heat pumps<br />

The AdaptiveFunction Plu s “Economy” function combines c omfort<br />

with l ow energy c ons umption. I n f act, by adjusti ng the set-point value, it<br />

opti mises compressor operation on the basis of t he actual wor king<br />

conditi ons.<br />

It is thus possible to achi eve significant s easonal energy savi ngs<br />

compared to water chillers and heat pumps of an equivalent power with<br />

traditional control logic.<br />

HIGH PRECISION water chillers and h eat pumps<br />

By using t he AdaptiveFunction Plus “Pr eci sion” function, it is possi ble<br />

to ac hieve as littl e fluct uation as possibl e, at partial capacities , in terms<br />

of t he average s et-point water t emperature deli vered t o t he users.<br />

Guaranteed rel iabil it y, even with water in the pipes onl y<br />

Thanks to the “Virtual T ank” f uncti on, Compac t-Y units with<br />

AdaptiveFunction Plu s can operate i n s ystems wit h a low wat er<br />

cont ent of down to 2 litres/ kW, even without the pres enc e of a water<br />

buffer tank, whilst still guaranteeing the reliability and good working<br />

order of the unit over ti me.<br />

Estimation of the syst em's therm al inertia<br />

Compact-Y units wit h AdaptiveFunction Plus are abl e t o esti mate t he<br />

charact eristics of t he thermal i nertia that regulates t he s ystem<br />

dynamics. T his is possi ble t hanks t o t he " ACM Autotuning” functi on,<br />

which proc esses the inf ormation relati ve to the progress of t he water<br />

temperatures, identif ying the opti mal value of the control paramet ers.<br />

Continuous system autodiagnosis<br />

The es timation function is al ways acti ve and makes it possibl e t o adapt<br />

the c ontr ol par ameters quic kl y t o every change in the wat er circuit and<br />

thus i n the s ystem water contents.<br />

Polyvalent EXPSYSTEMS units in R410A for efficient energy<br />

use<br />

Efficient en erg y u se<br />

EXPS YSTE MS is a lat est generation pol yval ent ecol ogical syst em,<br />

designed by RHOSS S.p.A. to offer c ooling, heati ng and hot water<br />

simultaneousl y or independently at any time of year, whilst<br />

guarant eeing efficient energy usage. Energy s avings are very high, with<br />

COP values of over 6 during the simultaneous production of chilled and<br />

hot water.<br />

With EXP SYST EMS , EFFICIENCY, RELIABILITY AND VERSATILITY ar e<br />

guarant eed, whilst offering great er environmental protec tion.<br />

Polyvalent units for residential and light commercial applications<br />

Four new units from 17 t o 34 kW in R 410A, able to c at er for t he t ypical<br />

demands of 2 and 4-pipe s ystems i n a flexible fas hion, so much s o in<br />

fact that they can be used in existing s ystems without any modific ations.<br />

They come compl ete wit h a wi de range of acc essories, which c an also<br />

be s upplied f actor y fitted.<br />