<strong>Operating</strong> <strong>Instructions</strong> <strong>Safety</strong> <strong>Switch</strong> <strong>CET</strong>.-<strong>AR</strong>-...-<strong>CH</strong>-...<br />

Caution!<br />

Requirements for connection cables<br />

Risk of damage to equipment or malfunctions as a result of incorrect connection<br />

cables.<br />

ÌÌUse connection components and connection cables from EU<strong>CH</strong>NER<br />

ÌÌOn the usage of other connection components, the requirements in the following<br />

table apply. EU<strong>CH</strong>NER provides no warranty for safe function in case<br />

of failure to comply with these requirements.<br />

Observe the following requirements with respect to the connection cables:<br />

For safety switch <strong>CET</strong>-<strong>AR</strong> with plug connectors 2 x M12<br />

Parameter Value Unit<br />

Wire cross-section min. 0.34 mm²<br />

R max. 60 W/km<br />

C max. 120 nF/km<br />

L max. 0.65 mH/km<br />

Recommended cable type<br />

LIYY 8x or 5x 0.34 mm²<br />

For safety switches <strong>CET</strong>-<strong>AR</strong> with plug connector RC18<br />

Parameter Value Unit<br />

Wire cross-section min. 0.34 mm²<br />

R max. 60 W/km<br />

C max. 120 nF/km<br />

L max. 0.65 mH/km<br />

Recommended cable type<br />

LIFY11Y min. 19-cores<br />