Operating Instructions Non-Contact Safety Switch CET.-AR-...-CH ...
Operating Instructions Non-Contact Safety Switch CET.-AR-...-CH ...
Operating Instructions Non-Contact Safety Switch CET.-AR-...-CH ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Operating</strong> <strong>Instructions</strong> <strong>Safety</strong> <strong>Switch</strong> <strong>CET</strong>.-<strong>AR</strong>-...-<strong>CH</strong>-...<br />
Caution!<br />
Requirements for connection cables<br />
Risk of damage to equipment or malfunctions as a result of incorrect connection<br />
cables.<br />
ÌÌUse connection components and connection cables from EU<strong>CH</strong>NER<br />
ÌÌOn the usage of other connection components, the requirements in the following<br />
table apply. EU<strong>CH</strong>NER provides no warranty for safe function in case<br />
of failure to comply with these requirements.<br />
Observe the following requirements with respect to the connection cables:<br />
For safety switch <strong>CET</strong>-<strong>AR</strong> with plug connectors 2 x M12<br />
Parameter Value Unit<br />
Wire cross-section min. 0.34 mm²<br />
R max. 60 W/km<br />
C max. 120 nF/km<br />
L max. 0.65 mH/km<br />
Recommended cable type<br />
LIYY 8x or 5x 0.34 mm²<br />
For safety switches <strong>CET</strong>-<strong>AR</strong> with plug connector RC18<br />
Parameter Value Unit<br />
Wire cross-section min. 0.34 mm²<br />
R max. 60 W/km<br />
C max. 120 nF/km<br />
L max. 0.65 mH/km<br />
Recommended cable type<br />
LIFY11Y min. 19-cores<br />
19