Plotter Setup<br />
Data Base<br />
GPS Engineering Display<br />
Dual Control Setup<br />
Lighting Setup<br />
DGPS Displays (slave reflects the conditions<br />
in master)<br />
Navigate Displays<br />
Position Displays<br />
Auxiliary Displays<br />
Tide Displays<br />
NMEA out Printer Out 2<br />
Waypoint Sorting<br />
Comments<br />
GPS Displays (slave reflects the conditions in master)<br />
Table D-2. Independently Controlled Functions<br />
Turning Master or Slave Units Off<br />
Before turning the power off to either the master or slave unit(s), it is recommended that<br />
the dual control function be disabled first. If not, the unit that remains on will alarm<br />
until the data link is re-established, the unit is turned off, or Dual Control is turned off.<br />
Backup Receiver Integrity Monitoring (BRIM)<br />
BRIM is a fault-detection and recovery algorythm in the MX51x software that compares<br />
position solutions between two independent systems. Whoever has the best accuracy<br />
becomes the unit in control. The basic requirements are; they are both MX51x models<br />
with its own GPS/DGPS smart antenna and both have the IM option enabled.<br />
This IM feature can be found under the CFG/Dual Control menu in units that has the IM<br />
license. This menu item is normally hidden and will show only when another MX51x unit<br />
has been detected.<br />
Multiple Unit Control Configuration<br />
The Multiple Unit Control mode allows you to connect one MX51x as a Master, up to<br />
two MX51x as Slave units, and up to three MX51x as Repeater units. The Repeater unit,<br />
however, only acts as a display unit. It has no capability to modify any setting unless<br />
a password (set by the Master unit in CFG1/Security) is entered. The Multiple Unit<br />
Control system must have a minimum of three MX51x and a maximum of five MX51x<br />
units altogether (see Table D-3). The system must have one Master and at least one<br />
Slave. This allows a common data base to be shared among the CDU control heads.<br />
This configuration also allows you to use one antenna connected to the Master unit for<br />
all CDUs. The remaining data ports, the MOB/Event input port, and the alarm output<br />
ports are still available on each unit for individual use on each CDU. This feature can be<br />
enabled in the CFG Dual Control menu.<br />
The hardware interface is accomplished by connecting the units together via an Ethernet<br />
switch (or hub). Refer to page 77 of this manual to setup LAN.<br />
152 | Appendix C - Multiple unit control