16.11.2014 Views

MX510/MX512 Operator & Installation Manual - Simrad Professional ...

MX510/MX512 Operator & Installation Manual - Simrad Professional ...

MX510/MX512 Operator & Installation Manual - Simrad Professional ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Plotter Setup<br />

Data Base<br />

GPS Engineering Display<br />

Dual Control Setup<br />

Lighting Setup<br />

DGPS Displays (slave reflects the conditions<br />

in master)<br />

Navigate Displays<br />

Position Displays<br />

Auxiliary Displays<br />

Tide Displays<br />

NMEA out Printer Out 2<br />

Waypoint Sorting<br />

Comments<br />

GPS Displays (slave reflects the conditions in master)<br />

Table D-2. Independently Controlled Functions<br />

Turning Master or Slave Units Off<br />

Before turning the power off to either the master or slave unit(s), it is recommended that<br />

the dual control function be disabled first. If not, the unit that remains on will alarm<br />

until the data link is re-established, the unit is turned off, or Dual Control is turned off.<br />

Backup Receiver Integrity Monitoring (BRIM)<br />

BRIM is a fault-detection and recovery algorythm in the MX51x software that compares<br />

position solutions between two independent systems. Whoever has the best accuracy<br />

becomes the unit in control. The basic requirements are; they are both MX51x models<br />

with its own GPS/DGPS smart antenna and both have the IM option enabled.<br />

This IM feature can be found under the CFG/Dual Control menu in units that has the IM<br />

license. This menu item is normally hidden and will show only when another MX51x unit<br />

has been detected.<br />

Multiple Unit Control Configuration<br />

The Multiple Unit Control mode allows you to connect one MX51x as a Master, up to<br />

two MX51x as Slave units, and up to three MX51x as Repeater units. The Repeater unit,<br />

however, only acts as a display unit. It has no capability to modify any setting unless<br />

a password (set by the Master unit in CFG1/Security) is entered. The Multiple Unit<br />

Control system must have a minimum of three MX51x and a maximum of five MX51x<br />

units altogether (see Table D-3). The system must have one Master and at least one<br />

Slave. This allows a common data base to be shared among the CDU control heads.<br />

This configuration also allows you to use one antenna connected to the Master unit for<br />

all CDUs. The remaining data ports, the MOB/Event input port, and the alarm output<br />

ports are still available on each unit for individual use on each CDU. This feature can be<br />

enabled in the CFG Dual Control menu.<br />

The hardware interface is accomplished by connecting the units together via an Ethernet<br />

switch (or hub). Refer to page 77 of this manual to setup LAN.<br />

152 | Appendix C - Multiple unit control

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!