<strong>Sonnet</strong> User’s <strong>Guide</strong><br />

is one or more of the run options shown in the table below. If you use<br />

multiple options they should be typed with no spaces in between after the minus<br />

sign. Note that other run options may be set in the Analysis Setup dialog box for<br />

your project and will be used during the analysis.<br />

-Dlicense<br />

Option<br />

Meaning<br />

Used for debugging em licensing problems. Displays all environment<br />

information relevant to licensing.<br />

-N Display number of subsections and estimated required memory. Em<br />

then exits without running a full analysis.<br />

-test<br />

Run em on a test circuit. Used to verify that em can get a license and<br />

run successfully.<br />

-v Display analysis information as the analysis is performed. The<br />

analysis information is output to the command prompt window or<br />

terminal from which the batch was executed.<br />

-AbsCacheNone<br />

-AbsCacheStopRestart<br />

-AbsCacheMultiSweep<br />

-AbsNoDiscrete<br />

-SubFreqHz[value]<br />

-ParamFile <br />

Disable ABS caching (overrides setting in project file).<br />

Enable ABS stop-restart caching (overrides setting in project file).<br />

Enable ABS multi-sweep plus stop-restart caching (overrides project<br />

file).<br />

Used when running ABS with pre-existing cache data. Tells the<br />

analysis engine not to do any more discrete frequencies. If preexisting<br />

cache data is sufficient to get converged ABS solution, then<br />

that solution is written to output. Otherwise, no processing is<br />

performed.<br />

where [value] is the subsectioning frequency in Hz. Note there is no<br />

space before the value field.<br />

This option allows subsectioning frequency to be specified on the<br />

command line, thereby overriding the settings in the project file.<br />

where is the name of a file which contains the value(s)<br />

which you wish to use for parameter(s) in the circuit being analyzed.<br />

These values override the value contained in the geometry project for<br />

the analysis, but do not change the contents of the geometry project.<br />

The syntax for the parameter file is =fnum where<br />

is the name of the parameter and fnum is a floating point<br />

number which defines the value of the parameter for the analysis.<br />